{"id":27804,"date":"2015-09-11T22:00:00","date_gmt":"2015-09-11T22:00:00","guid":{"rendered":"https:\/\/\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/"},"modified":"2022-01-26T15:22:37","modified_gmt":"2022-01-26T15:22:37","slug":"passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees","status":"publish","type":"white_papers","link":"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/","title":{"rendered":"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>Avant l&rsquo;apparition de la commutation de paquets1, les r\u00e9seaux \u00e0 commutation de circuits traitaient la transmission de la voix en utilisant un grand nombre d&rsquo;amplificateurs analogiques, \u00e9galiseurs et relais sol\u00e9no\u00efdes rotatifs. Les alimentations -48 V pour ce type de syst\u00e8me \u00e9taient compatibles avec les batteries au plomb-acide de grande capacit\u00e9 n\u00e9cessaires pour atteindre les objectifs stricts de tenue dans le temps. La source d&rsquo;\u00e9nergie branch\u00e9e sur le r\u00e9seau \u00e9lectrique \u00e9tait en g\u00e9n\u00e9ral non r\u00e9gul\u00e9e, avec des tensions de distribution allant de -75 V \u00e0 la limite haute du niveau de tension du r\u00e9seau, \u00e0 -36 V \u00e0 la fin du cycle de charge de la batterie de secours. Les syst\u00e8mes surchargeaient souvent les batteries au plomb-acide de l&rsquo;\u00e9poque, ce qui provoquait des fuites de vapeurs d&rsquo;acide. Les syst\u00e8mes de contr\u00f4le de la charge brute, l&rsquo;humidit\u00e9 et le manque d&rsquo;a\u00e9ration dans les locaux de charge des batteries de la zone, favorisaient la corrosion, de sorte que les ing\u00e9nieurs pr\u00e9f\u00e9raient utiliser la tension n\u00e9gative distribu\u00e9e car elle permet de minimiser et localiser les produits de corrosion.<\/p>\n","protected":false},"featured_media":27806,"template":"","tags":[],"company":[],"wp_category":[],"ppma_author":[1149],"class_list":["post-27804","white_papers","type-white_papers","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<title>Passez aux alimentations +48 V pour les applications de transmi...<\/title>\n<meta name=\"description\" content=\"Avant l&#039;apparition de la commutation de paquets1, les r\u00e9seaux \u00e0 commutation de circuits traitaient la transmission de la voix en utilisant un grand nombre...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/white_papers\/27804\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es\" \/>\n<meta property=\"og:description\" content=\"Avant l&#039;apparition de la commutation de paquets1, les r\u00e9seaux \u00e0 commutation de circuits traitaient la transmission de la voix en utilisant un grand nombre d&#039;amplificateurs analogiques, \u00e9galiseurs et relais sol\u00e9no\u00efdes rotatifs. Les alimentations -48 V pour ce type de syst\u00e8me \u00e9taient compatibles avec les batteries au plomb-acide de grande capacit\u00e9 n\u00e9cessaires pour atteindre les objectifs stricts de tenue dans le temps. La source d&#039;\u00e9nergie branch\u00e9e sur le r\u00e9seau \u00e9lectrique \u00e9tait en g\u00e9n\u00e9ral non r\u00e9gul\u00e9e, avec des tensions de distribution allant de -75 V \u00e0 la limite haute du niveau de tension du r\u00e9seau, \u00e0 -36 V \u00e0 la fin du cycle de charge de la batterie de secours. Les syst\u00e8mes surchargeaient souvent les batteries au plomb-acide de l&#039;\u00e9poque, ce qui provoquait des fuites de vapeurs d&#039;acide. Les syst\u00e8mes de contr\u00f4le de la charge brute, l&#039;humidit\u00e9 et le manque d&#039;a\u00e9ration dans les locaux de charge des batteries de la zone, favorisaient la corrosion, de sorte que les ing\u00e9nieurs pr\u00e9f\u00e9raient utiliser la tension n\u00e9gative distribu\u00e9e car elle permet de minimiser et localiser les produits de corrosion.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/white_papers\/27804\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-26T15:22:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci4882_vicor_va227-figure-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2100\" \/>\n\t<meta property=\"og:image:height\" content=\"1314\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/\",\"name\":\"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2015-09-11T22:00:00+00:00\",\"dateModified\":\"2022-01-26T15:22:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>","yoast_head_json":{"title":"Passez aux alimentations +48 V pour les applications de transmi...","description":"Avant l'apparition de la commutation de paquets1, les r\u00e9seaux \u00e0 commutation de circuits traitaient la transmission de la voix en utilisant un grand nombre...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/white_papers\/27804\/","og_locale":"fr_FR","og_type":"article","og_title":"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es","og_description":"Avant l'apparition de la commutation de paquets1, les r\u00e9seaux \u00e0 commutation de circuits traitaient la transmission de la voix en utilisant un grand nombre d'amplificateurs analogiques, \u00e9galiseurs et relais sol\u00e9no\u00efdes rotatifs. Les alimentations -48 V pour ce type de syst\u00e8me \u00e9taient compatibles avec les batteries au plomb-acide de grande capacit\u00e9 n\u00e9cessaires pour atteindre les objectifs stricts de tenue dans le temps. La source d'\u00e9nergie branch\u00e9e sur le r\u00e9seau \u00e9lectrique \u00e9tait en g\u00e9n\u00e9ral non r\u00e9gul\u00e9e, avec des tensions de distribution allant de -75 V \u00e0 la limite haute du niveau de tension du r\u00e9seau, \u00e0 -36 V \u00e0 la fin du cycle de charge de la batterie de secours. Les syst\u00e8mes surchargeaient souvent les batteries au plomb-acide de l'\u00e9poque, ce qui provoquait des fuites de vapeurs d'acide. Les syst\u00e8mes de contr\u00f4le de la charge brute, l'humidit\u00e9 et le manque d'a\u00e9ration dans les locaux de charge des batteries de la zone, favorisaient la corrosion, de sorte que les ing\u00e9nieurs pr\u00e9f\u00e9raient utiliser la tension n\u00e9gative distribu\u00e9e car elle permet de minimiser et localiser les produits de corrosion.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/white_papers\/27804\/","og_site_name":"EENewsEurope","article_modified_time":"2022-01-26T15:22:37+00:00","og_image":[{"width":2100,"height":1314,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci4882_vicor_va227-figure-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/","url":"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/","name":"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2015-09-11T22:00:00+00:00","dateModified":"2022-01-26T15:22:37+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/white_papers\/passez-aux-alimentations-48-v-pour-les-applications-de-transmission-de-donnees\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Passez aux alimentations +48 V pour les applications de transmission de donn\u00e9es"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/white_papers\/27804"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/white_papers"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/white_papers"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/27806"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=27804"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=27804"},{"taxonomy":"company","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/company?post=27804"},{"taxonomy":"wp_category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/wp_category?post=27804"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=27804"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}