{"id":97756,"date":"2019-01-22T23:31:44","date_gmt":"2019-01-22T23:31:44","guid":{"rendered":"https:\/\/\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/"},"modified":"2019-01-22T23:31:44","modified_gmt":"2019-01-22T23:31:44","slug":"filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/","title":{"rendered":"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences"},"content":{"rendered":"<p>La conception \u00e0 deux \u00e9tages fournit d\u2019excellentes performances d\u2019att\u00e9nuation dans une large plage de fr\u00e9quences allant de 100&nbsp;kHz \u00e0 100&nbsp;MHz et offre une protection contre les impulsions d\u2019entr\u00e9e haute tension. La s\u00e9rie RSKN \u00e0 usage g\u00e9n\u00e9ral convient \u00e0 un vaste \u00e9ventail d&rsquo;applications industrielles et de communication.<\/p>\n<p>Ces filtres sont propos\u00e9s en bo\u00eetiers m\u00e9talliques dont les tailles varient de 47 x 107 x 26&nbsp;mm (L x l x H) pour le mod\u00e8le de 6&nbsp;A, \u00e0 67 x 151 x 35&nbsp;mm pour le mod\u00e8le de 30&nbsp;A. Les borniers sont munis d\u2019un capot int\u00e9gral afin d\u2019\u00e9viter toute perte de mat\u00e9riel.<\/p>\n<p>Les filtres RSKN fonctionnent \u00e0 une temp\u00e9rature ambiante comprise entre -25&nbsp;\u00b0C&nbsp;et +85&nbsp;\u00b0C, avec un d\u00e9rating au-del\u00e0 de 50&nbsp;\u00b0C pour les mod\u00e8les de 6&nbsp;A et 10&nbsp;A, et au-del\u00e0 de 45&nbsp;\u00b0C pour les mod\u00e8les de 20&nbsp;A et 30&nbsp;A. Tous les mod\u00e8les sont certifi\u00e9s conformes aux normes de s\u00e9curit\u00e9 UL1283, CSA C22.2 n\u00b0&nbsp;8 et EN60939. Ils respectent \u00e9galement la directive RoHS2. Ces produits sont garantis 5 ans.<\/p>\n<p><a href=\"http:\/\/www.fr.tdk-lambda.com\/rskn\">www.fr.tdk-lambda.com\/rskn<\/a><\/p>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/convertisseurs-dc-dc-double-sortie-15-w-et-30-w-dotes-dun-blindage-sur-les-six-faces\">Convertisseurs DC-DC \u00e0 double sortie 15 W et 30 W dot\u00e9s d\u2019un blindage sur les six faces<\/a><\/h3>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/alimentations-programmables-dc-de-5-kw-1u\">Alimentations programmables DC de 5 kW 1U<\/a><\/h3>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/le-marche-des-capteurs-ultra-sons-mems-decolle\">Le march\u00e9 des capteurs Ultra-sons MEMS d\u00e9colle<\/a><\/h3>\n","protected":false},"excerpt":{"rendered":"<p>TDK Corporation annonce le lancement de la s\u00e9rie RSKN de filtres CEM d\u2019une tension assign\u00e9e de 250 V AC\/DC pour une intensit\u00e9 de 6 A, 10 A, 20 A et 30 A.<\/p>\n","protected":false},"author":9,"featured_media":97757,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1141],"class_list":["post-97756","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuatio...<\/title>\n<meta name=\"description\" content=\"TDK Corporation annonce le lancement de la s\u00e9rie RSKN de filtres CEM d\u2019une tension assign\u00e9e de 250 V AC\/DC pour une intensit\u00e9 de 6 A, 10 A, 20 A et 30...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/97756\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences\" \/>\n<meta property=\"og:description\" content=\"TDK Corporation annonce le lancement de la s\u00e9rie RSKN de filtres CEM d\u2019une tension assign\u00e9e de 250 V AC\/DC pour une intensit\u00e9 de 6 A, 10 A, 20 A et 30 A.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/97756\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2019-01-22T23:31:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7725_tdk.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2100\" \/>\n\t<meta property=\"og:image:height\" content=\"1500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#\\\/schema\\\/person\\\/fb91a9468f3bd41fa1a31b475e2ea1fc\"},\"headline\":\"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences\",\"datePublished\":\"2019-01-22T23:31:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/\"},\"wordCount\":247,\"publisher\":{\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ecinews.fr\\\/wp-content\\\/uploads\\\/import\\\/default\\\/files\\\/sites\\\/default\\\/files\\\/images\\\/eci7725_tdk.jpg\",\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/\",\"url\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/\",\"name\":\"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences -\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ecinews.fr\\\/wp-content\\\/uploads\\\/import\\\/default\\\/files\\\/sites\\\/default\\\/files\\\/images\\\/eci7725_tdk.jpg\",\"datePublished\":\"2019-01-22T23:31:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.ecinews.fr\\\/wp-content\\\/uploads\\\/import\\\/default\\\/files\\\/sites\\\/default\\\/files\\\/images\\\/eci7725_tdk.jpg\",\"contentUrl\":\"https:\\\/\\\/www.ecinews.fr\\\/wp-content\\\/uploads\\\/import\\\/default\\\/files\\\/sites\\\/default\\\/files\\\/images\\\/eci7725_tdk.jpg\",\"width\":2100,\"height\":1500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ecinews.fr\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.ecinews.fr\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/logo-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.ecinews.fr\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eenewseurope.com\\\/en\\\/#\\\/schema\\\/person\\\/fb91a9468f3bd41fa1a31b475e2ea1fc\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g4f02d5f56e3df527135c80dad2587e75\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuatio...","description":"TDK Corporation annonce le lancement de la s\u00e9rie RSKN de filtres CEM d\u2019une tension assign\u00e9e de 250 V AC\/DC pour une intensit\u00e9 de 6 A, 10 A, 20 A et 30...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/97756\/","og_locale":"fr_FR","og_type":"article","og_title":"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences","og_description":"TDK Corporation annonce le lancement de la s\u00e9rie RSKN de filtres CEM d\u2019une tension assign\u00e9e de 250 V AC\/DC pour une intensit\u00e9 de 6 A, 10 A, 20 A et 30 A.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/97756\/","og_site_name":"EENewsEurope","article_published_time":"2019-01-22T23:31:44+00:00","og_image":[{"width":2100,"height":1500,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7725_tdk.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/fb91a9468f3bd41fa1a31b475e2ea1fc"},"headline":"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences","datePublished":"2019-01-22T23:31:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/"},"wordCount":247,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"image":{"@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7725_tdk.jpg","articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/","url":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/","name":"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#primaryimage"},"image":{"@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7725_tdk.jpg","datePublished":"2019-01-22T23:31:44+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#primaryimage","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7725_tdk.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7725_tdk.jpg","width":2100,"height":1500},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/filtres-cem-monophases-de-6-a-a-30-a-assurant-une-attenuation-dans-une-large-plage-de-frequences\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Filtres CEM monophas\u00e9s de 6 A \u00e0 30 A assurant une att\u00e9nuation dans une large plage de fr\u00e9quences"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/fb91a9468f3bd41fa1a31b475e2ea1fc","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g4f02d5f56e3df527135c80dad2587e75","url":"https:\/\/secure.gravatar.com\/avatar\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/d1954b3575425d2e33064e42fef5b80001d9444ec0b6e4a334f6b607d5dd9368?s=96&d=mm&r=g","author_category":"","user_url":"","last_name":"Dieul","first_name":"Alain","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/97756","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=97756"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/97756\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/97757"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=97756"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=97756"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=97756"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=97756"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=97756"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}