{"id":445217,"date":"2024-03-04T12:25:58","date_gmt":"2024-03-04T11:25:58","guid":{"rendered":"https:\/\/www.ecinews.fr\/?p=445217"},"modified":"2024-03-04T12:25:58","modified_gmt":"2024-03-04T11:25:58","slug":"relais-10a-avec-rigidite-dielectrique-elevee","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/","title":{"rendered":"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e"},"content":{"rendered":"<h3>Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents, l\u2019automatisation des usines et les applications d\u2019\u00e9nergie. Le mod\u00e8le le plus r\u00e9cent assure des charges de courant pouvant atteindre 10\u00a0A, avec une rigidit\u00e9 di\u00e9lectrique nominale de 6\u00a0000\u00a0V\u00a0CA, une haute sensibilit\u00e9 avec une consommation de bobine de\u00a0220\u00a0mW.<\/h3>\n<p>Les nouveaux relais G6RN-E offrent davantage de s\u00e9curit\u00e9 et sont conformes aux crit\u00e8res d\u2019essai au fil incandescent de la norme CEI\/EN60335-1, portant sur les appareils \u00e9lectriques pour environnement domestique et usage collectif, ainsi qu\u2019\u00e0 ceux de la norme CEI\/EN60079-15 sur les atmosph\u00e8res explosives. Ils sont aussi conformes aux normes de s\u00e9curit\u00e9 internationales pour la r\u00e9sistance \u00e0 l\u2019inflammation. Cela en fait des solutions id\u00e9ales pour assurer la s\u00e9curit\u00e9 des \u00e9quipements de climatisation, tels que les climatiseurs et les pompes \u00e0 chaleur.<\/p>\n<p>L\u2019originalit\u00e9 des relais G6RN-E r\u00e9side dans un bo\u00eetier de protection contre les flux, assurant une tension di\u00e9lectrique de 6\u00a0000\u00a0V\u00a0AC entre la bobine et le contact. Les autres caract\u00e9ristiques incluent un isolement \u00e9lev\u00e9 avec une distance d\u2019isolement de 8\u00a0mm, une tension de tenue aux chocs de 10\u00a0kV entre la bobine et les contacts, une haute sensibilit\u00e9 avec une consommation de bobine de 220\u00a0mW et une temp\u00e9rature de fonctionnement ambiante de 85\u00a0\u00b0C, sans oublier la conformit\u00e9 du mod\u00e8le standard avec les normes UL et VDE. La conformit\u00e9 aux applications d\u2019automatisation recommand\u00e9es pour les b\u00e2timents et les usines concerne \u00e9galement les contr\u00f4leurs de pompes \u00e0 chaleur et les onduleurs, ainsi que les chaudi\u00e8res au gaz, les contr\u00f4leurs de temp\u00e9rature et les automates programmables (PLC). La disposition des bornes et les valeurs nominales de contact sont identiques \u00e0 celles des relais Omron G6RL existants ayant les m\u00eames broches.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.omron.com\/global\/fr\/\">https:\/\/www.omron.com\/global\/fr\/<\/a><\/p>\n<p><a href=\"https:\/\/news.google.com\/publications\/CAAqBwgKMJbcwQswuPfYAw?hl=fr&amp;gl=BE&amp;ceid=BE:fr\">Suivre ECInews sur Google news<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents, l\u2019automatisation des usines et les applications d\u2019\u00e9nergie. Le mod\u00e8le le plus r\u00e9cent assure des charges de courant pouvant atteindre 10\u00a0A, avec une rigidit\u00e9 di\u00e9lectrique nominale de 6\u00a0000\u00a0V\u00a0CA, une haute sensibilit\u00e9 avec une consommation de [&hellip;]<\/p>\n","protected":false},"author":36,"featured_media":445218,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[1532],"domains":[47],"ppma_author":[1154],"class_list":["post-445217","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","tag-relais","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e ...<\/title>\n<meta name=\"description\" content=\"Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents,...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/445217\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e\" \/>\n<meta property=\"og:description\" content=\"Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents, l\u2019automatisation des usines et les applications d\u2019\u00e9nergie.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/445217\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-04T11:25:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/test.ecinews.fr\/wp-content\/uploads\/2024\/03\/ECI3907_Omron-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"848\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/e4387676ad67ce722325c7832f3c3762\"},\"headline\":\"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e\",\"datePublished\":\"2024-03-04T11:25:58+00:00\",\"dateModified\":\"2024-03-04T11:25:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/\"},\"wordCount\":339,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"keywords\":[\"Relais\"],\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/\",\"url\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/\",\"name\":\"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2024-03-04T11:25:58+00:00\",\"dateModified\":\"2024-03-04T11:25:58+00:00\",\"description\":\"Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents, l\u2019automatisation des usines et les applications d\u2019\u00e9nergie.\",\"breadcrumb\":{\"@id\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cdn.eenewseurope.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/e4387676ad67ce722325c7832f3c3762\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/736120675699dbbf0f0f282b9a9cfb75\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/bc93b056d07515be5b8eecd4acf49c5c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/bc93b056d07515be5b8eecd4acf49c5c?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"},\"sameAs\":[\"http:\/\/ECINews\"]}]}<\/script>","yoast_head_json":{"title":"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e ...","description":"Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents,...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/445217\/","og_locale":"fr_FR","og_type":"article","og_title":"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e","og_description":"Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents, l\u2019automatisation des usines et les applications d\u2019\u00e9nergie.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/445217\/","og_site_name":"EENewsEurope","article_published_time":"2024-03-04T11:25:58+00:00","og_image":[{"width":1080,"height":848,"url":"https:\/\/test.ecinews.fr\/wp-content\/uploads\/2024\/03\/ECI3907_Omron-scaled.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/#article","isPartOf":{"@id":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/e4387676ad67ce722325c7832f3c3762"},"headline":"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e","datePublished":"2024-03-04T11:25:58+00:00","dateModified":"2024-03-04T11:25:58+00:00","mainEntityOfPage":{"@id":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/"},"wordCount":339,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"keywords":["Relais"],"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/","url":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/","name":"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2024-03-04T11:25:58+00:00","dateModified":"2024-03-04T11:25:58+00:00","description":"Omron Electronic Components Europe \u00e9largit son offre de relais avec l\u2019introduction du G6RN-E pour les pompes \u00e0 chaleur, les b\u00e2timents intelligents, l\u2019automatisation des usines et les applications d\u2019\u00e9nergie.","breadcrumb":{"@id":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/test.ecinews.fr\/fr\/relais-10a-avec-rigidite-dielectrique-elevee\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cdn.eenewseurope.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Relais 10A avec rigidit\u00e9 di\u00e9lectrique \u00e9lev\u00e9e"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/e4387676ad67ce722325c7832f3c3762","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/736120675699dbbf0f0f282b9a9cfb75","url":"https:\/\/secure.gravatar.com\/avatar\/bc93b056d07515be5b8eecd4acf49c5c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bc93b056d07515be5b8eecd4acf49c5c?s=96&d=mm&r=g","caption":"Alain Dieul"},"sameAs":["http:\/\/ECINews"]}]}},"authors":[{"term_id":1154,"user_id":36,"is_guest":0,"slug":"alain-dieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/bc93b056d07515be5b8eecd4acf49c5c?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/445217"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/36"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=445217"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/445217\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/445218"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=445217"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=445217"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=445217"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=445217"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=445217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}