{"id":226104,"date":"2013-01-20T23:00:00","date_gmt":"2013-01-20T23:00:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/processeurs-de-mesure-denergie-monophasee\/"},"modified":"2013-01-20T23:00:00","modified_gmt":"2013-01-20T23:00:00","slug":"processeurs-de-mesure-denergie-monophasee","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/","title":{"rendered":"Processeurs de mesure d&rsquo;\u00e9nergie monophas\u00e9e"},"content":{"rendered":"<p>Ces deux dispositifs contiennent un firmware unique adapt&eacute; aux besoins de l&rsquo;application finale. Le 78M6610+PSU (Power-Supply Units) est sp&eacute;cialement con&ccedil;u pour la supervision en temps r&eacute;el des centres de traitement de donn&eacute;es, des serveurs, et des &eacute;quipements de t&eacute;l&eacute;com, tandis que le 78M6610+LMU (Load Monitoring Units) est une solution &agrave; usage plus g&eacute;n&eacute;ral, pour des applications telles que les produits blancs, les prises intelligentes, les chargeurs EV, ou les convertisseurs solaires.<br \/>\nCes composants permettent aux utilisateurs d&rsquo;ajouter facilement un compteur d&rsquo;&eacute;nergie complet &agrave; une conception existante sans surco&ucirc;t significatif ni re-conception. En outre, la souplesse de l&rsquo;interface de mesure et de l&rsquo;interface h&ocirc;te, permet une int&eacute;gration facile dans n&rsquo;importe quel syst&egrave;me. De hautes performances, ces circuits assurent la d&eacute;tection de l&rsquo;alimentation r&eacute;seau sur toute la plage dynamique de courant de charge et de modes de coupure. Ils int&egrave;grent un oscillateur RC et une interface s&eacute;rie bas d&eacute;bit &eacute;vitant le recours aux quartzs fragiles et co&ucirc;teux. Ils sont propos&eacute;s en bo&icirc;tiers QFN 24 contacts et, pour la version PSU, en TSSOP 16 broches.<br \/>\n&quot;Pour offrir un meilleur rendement, un smart grid (r&eacute;seau de distribution intelligent) doit pouvoir mesurer l&rsquo;&eacute;nergie au niveau des diff&eacute;rents points de charge, au-del&agrave; de ce que permet un compteur &eacute;lectrique traditionnel,&quot; d&eacute;clare Kris Ardis, Directeur Produits Smart Grid, chez Maxim Integrated. &quot;Les 78M6610+PSU et 78M6610+LMU permettent de r&eacute;aliser ces mesures avec une grande pr&eacute;cision, avec un firmware sp&eacute;cifique &agrave; l&rsquo;application, et pour un co&ucirc;t syst&egrave;me r&eacute;duit.&quot;<br \/>\n&quot;Les smart grids ont absolument besoin de ce type de fonctionnalit&eacute;,&quot; d&eacute;clare Christine Hertzog, Directrice G&eacute;n&eacute;rale de Smart Grid Library. &quot;Disposer de fonctions de mesure et de diagnostic d&rsquo;&eacute;nergie dans les data centers (centres de traitement de donn&eacute;es), les convertisseurs solaires, et les appareils m&eacute;nagers, am&eacute;liore la s&eacute;curit&eacute;, le rendement &eacute;nerg&eacute;tique, et les &eacute;conomies d&rsquo;&eacute;nergie.&quot;<\/p>\n<p><a title=\"www.maximintegrated.com\/datasheet\/index.mvp\/id\/7814\" target=\"_blank\" href=\"http:\/\/www.maximintegrated.com\/datasheet\/index.mvp\/id\/7814\" rel=\"noopener\">www.maximintegrated.com\/datasheet\/index.mvp\/id\/7814<\/a><\/p>\n<p><a title=\"www.maximintegrated.com\/datasheet\/index.mvp\/id\/7793\" target=\"_blank\" href=\"http:\/\/www.maximintegrated.com\/datasheet\/index.mvp\/id\/7793\" rel=\"noopener\">www.maximintegrated.com\/datasheet\/index.mvp\/id\/7793<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sous-syst\u00e8mes de mesure d&rsquo;\u00e9nergie int\u00e9gr\u00e9s sur une seule puce, les processeurs de mesure d&rsquo;\u00e9nergie monophas\u00e9e 78M6610+PSU et 78M6610+LMU de Maxim Integrated Products permettent d&rsquo;offrir des fonctions de d\u00e9tection et de diagnostic du r\u00e9seau \u00e9lectrique \u00e0 des conceptions existantes, sans le co\u00fbt d&rsquo;un SoC compteur \u00e9lectrique classique.<\/p>\n","protected":false},"author":22,"featured_media":226105,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1149],"class_list":["post-226104","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Processeurs de mesure d&#039;\u00e9nergie monophas\u00e9e ...<\/title>\n<meta name=\"description\" content=\"Sous-syst\u00e8mes de mesure d&#039;\u00e9nergie int\u00e9gr\u00e9s sur une seule puce, les processeurs de mesure d&#039;\u00e9nergie monophas\u00e9e 78M6610+PSU et 78M6610+LMU de Maxim...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/226104\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Processeurs de mesure d&#039;\u00e9nergie monophas\u00e9e\" \/>\n<meta property=\"og:description\" content=\"Sous-syst\u00e8mes de mesure d&#039;\u00e9nergie int\u00e9gr\u00e9s sur une seule puce, les processeurs de mesure d&#039;\u00e9nergie monophas\u00e9e 78M6610+PSU et 78M6610+LMU de Maxim Integrated Products permettent d&#039;offrir des fonctions de d\u00e9tection et de diagnostic du r\u00e9seau \u00e9lectrique \u00e0 des conceptions existantes, sans le co\u00fbt d&#039;un SoC compteur \u00e9lectrique classique.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/226104\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2013-01-20T23:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci6335_max_78m6610.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1772\" \/>\n\t<meta property=\"og:image:height\" content=\"1265\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eeNews Europe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eeNews Europe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/\"},\"author\":{\"name\":\"eeNews Europe\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\"},\"headline\":\"Processeurs de mesure d&rsquo;\u00e9nergie monophas\u00e9e\",\"datePublished\":\"2013-01-20T23:00:00+00:00\",\"dateModified\":\"2013-01-20T23:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/\"},\"wordCount\":423,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/\",\"name\":\"Processeurs de mesure d'\u00e9nergie monophas\u00e9e -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#website\"},\"datePublished\":\"2013-01-20T23:00:00+00:00\",\"dateModified\":\"2013-01-20T23:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Processeurs de mesure d&rsquo;\u00e9nergie monophas\u00e9e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/fr\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\",\"name\":\"eeNews Europe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"caption\":\"eeNews Europe\"}}]}<\/script>","yoast_head_json":{"title":"Processeurs de mesure d'\u00e9nergie monophas\u00e9e ...","description":"Sous-syst\u00e8mes de mesure d'\u00e9nergie int\u00e9gr\u00e9s sur une seule puce, les processeurs de mesure d'\u00e9nergie monophas\u00e9e 78M6610+PSU et 78M6610+LMU de Maxim...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/226104\/","og_locale":"fr_FR","og_type":"article","og_title":"Processeurs de mesure d'\u00e9nergie monophas\u00e9e","og_description":"Sous-syst\u00e8mes de mesure d'\u00e9nergie int\u00e9gr\u00e9s sur une seule puce, les processeurs de mesure d'\u00e9nergie monophas\u00e9e 78M6610+PSU et 78M6610+LMU de Maxim Integrated Products permettent d'offrir des fonctions de d\u00e9tection et de diagnostic du r\u00e9seau \u00e9lectrique \u00e0 des conceptions existantes, sans le co\u00fbt d'un SoC compteur \u00e9lectrique classique.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/226104\/","og_site_name":"EENewsEurope","article_published_time":"2013-01-20T23:00:00+00:00","og_image":[{"width":1772,"height":1265,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci6335_max_78m6610.jpg","type":"image\/jpeg"}],"author":"eeNews Europe","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eeNews Europe","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/"},"author":{"name":"eeNews Europe","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4"},"headline":"Processeurs de mesure d&rsquo;\u00e9nergie monophas\u00e9e","datePublished":"2013-01-20T23:00:00+00:00","dateModified":"2013-01-20T23:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/"},"wordCount":423,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/","url":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/","name":"Processeurs de mesure d'\u00e9nergie monophas\u00e9e -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#website"},"datePublished":"2013-01-20T23:00:00+00:00","dateModified":"2013-01-20T23:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/processeurs-de-mesure-denergie-monophasee\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Processeurs de mesure d&rsquo;\u00e9nergie monophas\u00e9e"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/fr\/#website","url":"https:\/\/www.eenewseurope.com\/fr\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/fr\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4","name":"eeNews Europe","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22","url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","caption":"eeNews Europe"}}]}},"authors":[{"term_id":1149,"user_id":22,"is_guest":0,"slug":"eenews-europe","display_name":"eeNews Europe","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/226104"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=226104"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/226104\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/226105"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=226104"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=226104"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=226104"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=226104"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=226104"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}