{"id":223569,"date":"2012-02-13T23:00:00","date_gmt":"2012-02-13T23:00:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/"},"modified":"2012-02-13T23:00:00","modified_gmt":"2012-02-13T23:00:00","slug":"thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/","title":{"rendered":"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils"},"content":{"rendered":"<p class=\"MsoNormal\">Ces deux r&eacute;f&eacute;rences offrent une vari&eacute;t&eacute; d&rsquo;options facilitant la conception. Une interface SPI ou 3 fils est disponible pour la lecture ou l&rsquo;&eacute;criture de donn&eacute;es. La r&eacute;solution de lecture est ajustable par l&rsquo;utilisateur de 9 &agrave; 12 bits pour les applications exigeant une haute r&eacute;solution en temp&eacute;rature. Les MAX31723 (&plusmn;0,5&deg;C) et MAX31722 (&plusmn;2&deg;C) satisfont aux applications de basse aussi bien que de haute pr&eacute;cision.<br \/>\nCes circuits permettent de r&eacute;gler les seuils de thermostat et les registres de configuration dans une m&eacute;moire non volatile, avant ou pendant le placement du composant, sans avoir &agrave; le reprogrammer &agrave; chaque allumage. Cette m&eacute;moire non volatile augmente par ailleurs la fiabilit&eacute; syst&egrave;me en &eacute;vitant les pertes de donn&eacute;es en cas de coupure impr&eacute;vue d&rsquo;alimentation.&nbsp;<br \/>\nLes deux dispositifs offrent deux modes de conversion de temp&eacute;rature, s&eacute;lectionnables par l&rsquo;utilisateur. Le mode ponctuel, ou 1-shot, permet au dispositif de limiter sa consommation, en se r&eacute;veillant pour ex&eacute;cuter une conversion de temp&eacute;rature, uniquement sur demande de l&rsquo;utilisateur. Le mode continu lui permet de surveiller la temp&eacute;rature en mode autonome, de mani&egrave;re &agrave; soulager le processeur du syst&egrave;me.<br \/>\nLa plage d&rsquo;alimentation de ces circuits s&rsquo;&eacute;tend de 1,7&nbsp;V &agrave; 3,7&nbsp;V. Ils fonctionnent et peuvent ex&eacute;cuter des mesures dans la plage de temp&eacute;rature de -55 &deg;C &agrave; +125 &deg;C. Les deux composants sont encapsul&eacute;s en bo&icirc;tiers propri&eacute;taires &micro;MAX &agrave; 8 broches.<\/p>\n<p class=\"MsoNormal\"><a href=\"http:\/\/www.maxim-ic.com\/\">www.maxim-ic.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Maxim Integrated Products introduit les thermom\u00e8tres et thermostats num\u00e9riques MAX31722 et MAX31723. Ces dispositifs d\u00e9livrent les valeurs de temp\u00e9rature lues localement sur une interface SPI ou 3 fils, selon le choix de l\u2019utilisateur et ne n\u00e9cessitent aucun composant additionnel. Ils peuvent \u00eatre aliment\u00e9s \u00e0 partir d\u2019une tension aussi basse que 1,7 V.<\/p>\n","protected":false},"author":22,"featured_media":223570,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1149],"class_list":["post-223569","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec inte...<\/title>\n<meta name=\"description\" content=\"Maxim Integrated Products introduit les thermom\u00e8tres et thermostats num\u00e9riques MAX31722 et MAX31723. Ces dispositifs d\u00e9livrent les valeurs de temp\u00e9rature...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223569\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils\" \/>\n<meta property=\"og:description\" content=\"Maxim Integrated Products introduit les thermom\u00e8tres et thermostats num\u00e9riques MAX31722 et MAX31723. Ces dispositifs d\u00e9livrent les valeurs de temp\u00e9rature lues localement sur une interface SPI ou 3 fils, selon le choix de l\u2019utilisateur et ne n\u00e9cessitent aucun composant additionnel. Ils peuvent \u00eatre aliment\u00e9s \u00e0 partir d\u2019une tension aussi basse que 1,7 V.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223569\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2012-02-13T23:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/test.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci6062_max31722-23.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1665\" \/>\n\t<meta property=\"og:image:height\" content=\"932\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eeNews Europe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eeNews Europe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/\"},\"author\":{\"name\":\"eeNews Europe\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\"},\"headline\":\"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils\",\"datePublished\":\"2012-02-13T23:00:00+00:00\",\"dateModified\":\"2012-02-13T23:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/\"},\"wordCount\":316,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/\",\"url\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/\",\"name\":\"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#website\"},\"datePublished\":\"2012-02-13T23:00:00+00:00\",\"dateModified\":\"2012-02-13T23:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/fr\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\",\"name\":\"eeNews Europe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"caption\":\"eeNews Europe\"}}]}<\/script>","yoast_head_json":{"title":"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec inte...","description":"Maxim Integrated Products introduit les thermom\u00e8tres et thermostats num\u00e9riques MAX31722 et MAX31723. Ces dispositifs d\u00e9livrent les valeurs de temp\u00e9rature...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223569\/","og_locale":"fr_FR","og_type":"article","og_title":"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils","og_description":"Maxim Integrated Products introduit les thermom\u00e8tres et thermostats num\u00e9riques MAX31722 et MAX31723. Ces dispositifs d\u00e9livrent les valeurs de temp\u00e9rature lues localement sur une interface SPI ou 3 fils, selon le choix de l\u2019utilisateur et ne n\u00e9cessitent aucun composant additionnel. Ils peuvent \u00eatre aliment\u00e9s \u00e0 partir d\u2019une tension aussi basse que 1,7 V.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223569\/","og_site_name":"EENewsEurope","article_published_time":"2012-02-13T23:00:00+00:00","og_image":[{"width":1665,"height":932,"url":"https:\/\/test.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci6062_max31722-23.jpg","type":"image\/jpeg"}],"author":"eeNews Europe","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eeNews Europe","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/#article","isPartOf":{"@id":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/"},"author":{"name":"eeNews Europe","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4"},"headline":"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils","datePublished":"2012-02-13T23:00:00+00:00","dateModified":"2012-02-13T23:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/"},"wordCount":316,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/","url":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/","name":"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#website"},"datePublished":"2012-02-13T23:00:00+00:00","dateModified":"2012-02-13T23:00:00+00:00","breadcrumb":{"@id":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/test.ecinews.fr\/fr\/thermometres-thermostats-numeriques-basse-tension-avec-interface-polyvalente-spi-ou-3-fils\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Thermom\u00e8tres \/ thermostats num\u00e9riques basse tension avec interface polyvalente SPI ou 3 fils"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/fr\/#website","url":"https:\/\/www.eenewseurope.com\/fr\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/fr\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4","name":"eeNews Europe","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/fr\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22","url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","caption":"eeNews Europe"}}]}},"authors":[{"term_id":1149,"user_id":22,"is_guest":0,"slug":"eenews-europe","display_name":"eeNews Europe","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223569"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=223569"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223569\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/223570"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=223569"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=223569"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=223569"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=223569"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=223569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}