{"id":223019,"date":"2011-11-22T23:00:00","date_gmt":"2011-11-22T23:00:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/"},"modified":"2011-11-22T23:00:00","modified_gmt":"2011-11-22T23:00:00","slug":"alimentations-dc-250-350-w-dans-un-format-de-3-x-5","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/","title":{"rendered":"Alimentations DC 250\/350 W dans un format de  3\u2019\u2019 x 5\u2019\u2019"},"content":{"rendered":"<p class=\"MsoNormal\">Les alimentations s&eacute;ries EMH250 et EMH350 acceptent une tension d&rsquo;entr&eacute;e de 80 &agrave; 275 VAC et sont disponibles en quatre mod&egrave;les couvrant les tensions nominales de sortie de +12, +18, +24 ou +48 VDC. Une fonction Trim permet l&rsquo;ajustement de la tension &agrave; +\/- 10% de la valeur nominale. Tous ces mod&egrave;les disposent d&rsquo;une sortie compl&eacute;mentaire +12 VDC \/ 0.6 A pour alimenter un ventilateur. En plus, la version 350 W d&eacute;livre un +5 VDC \/ 2.0 A standby. La pleine puissance est disponible d&egrave;s 90 VAC et sans derating jusqu&rsquo;&agrave; +50 &deg;C de temp&eacute;rature de fonctionnement.<br \/>\nMesurant seulement&nbsp; 76.2 x 127 x 36.3 mm (3&rdquo; x 5&rdquo; x 1&rdquo;.43), ces alimentations ne n&eacute;cessitent que 12 CFM de ventilation pour d&eacute;livrer leur pleine puissance. Un capot avec ventilateur sur le dessus peut donc &ecirc;tre fourni en option et l&rsquo;EMH350 offre l&rsquo;option suppl&eacute;mentaire d&rsquo;un ventilateur &agrave; vitesse variable en fonction de la temp&eacute;rature de l&rsquo;alimentation. Cette version est aussi disponible avec un circuit de diodes qui permet l&rsquo;&eacute;quilibrage des courants pour les configurations &agrave; redondance&nbsp; N+1.<br \/>\nUn choix de contr&ocirc;les analogiques ou digitaux est &eacute;galement propos&eacute;. Les signaux analogiques fournissent Power Fail, Inhibit et l&rsquo;&eacute;quilibrage du courant. Les signaux digitaux sont accessibles &agrave; travers un bus compatible PMBus.<\/p>\n<p><a href=\"http:\/\/www.xppower.com\" target=\"_blank\" title=\"www.xppower.com\" rel=\"noopener\">www.xppower.com<\/a> <\/p>\n","protected":false},"excerpt":{"rendered":"<p>XP Power annonce des alimentations \u00e0 d\u00e9coupage mono tension haut rendement de puissance respective de 250 et 350 W. R\u00e9pondant aux normes de s\u00e9curit\u00e9  UL\/TUV\/EN 60950-1 et  UL\/TUV\/EN 60601-1 pour les \u00e9quipements m\u00e9dicaux, ces s\u00e9ries conviennent \u00e0 un grand nombre d\u2019applications industrielles, m\u00e9dicales et chirurgicales.<\/p>\n","protected":false},"author":22,"featured_media":223020,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1149],"class_list":["post-223019","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019 ...<\/title>\n<meta name=\"description\" content=\"XP Power annonce des alimentations \u00e0 d\u00e9coupage mono tension haut rendement de puissance respective de 250 et 350 W. R\u00e9pondant aux normes de s\u00e9curit\u00e9 ...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223019\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019\" \/>\n<meta property=\"og:description\" content=\"XP Power annonce des alimentations \u00e0 d\u00e9coupage mono tension haut rendement de puissance respective de 250 et 350 W. R\u00e9pondant aux normes de s\u00e9curit\u00e9 UL\/TUV\/EN 60950-1 et UL\/TUV\/EN 60601-1 pour les \u00e9quipements m\u00e9dicaux, ces s\u00e9ries conviennent \u00e0 un grand nombre d\u2019applications industrielles, m\u00e9dicales et chirurgicales.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223019\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2011-11-22T23:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci6024_xpe0146-emh250-350.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"2100\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eeNews Europe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eeNews Europe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/\"},\"author\":{\"name\":\"eeNews Europe\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\"},\"headline\":\"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019\",\"datePublished\":\"2011-11-22T23:00:00+00:00\",\"dateModified\":\"2011-11-22T23:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/\"},\"wordCount\":252,\"publisher\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/\",\"name\":\"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019 -\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#website\"},\"datePublished\":\"2011-11-22T23:00:00+00:00\",\"dateModified\":\"2011-11-22T23:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#website\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ecinews.fr\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\",\"name\":\"eeNews Europe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"caption\":\"eeNews Europe\"}}]}<\/script>","yoast_head_json":{"title":"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019 ...","description":"XP Power annonce des alimentations \u00e0 d\u00e9coupage mono tension haut rendement de puissance respective de 250 et 350 W. R\u00e9pondant aux normes de s\u00e9curit\u00e9 ...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223019\/","og_locale":"fr_FR","og_type":"article","og_title":"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019","og_description":"XP Power annonce des alimentations \u00e0 d\u00e9coupage mono tension haut rendement de puissance respective de 250 et 350 W. R\u00e9pondant aux normes de s\u00e9curit\u00e9 UL\/TUV\/EN 60950-1 et UL\/TUV\/EN 60601-1 pour les \u00e9quipements m\u00e9dicaux, ces s\u00e9ries conviennent \u00e0 un grand nombre d\u2019applications industrielles, m\u00e9dicales et chirurgicales.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223019\/","og_site_name":"EENewsEurope","article_published_time":"2011-11-22T23:00:00+00:00","og_image":[{"width":1500,"height":2100,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci6024_xpe0146-emh250-350.jpg","type":"image\/jpeg"}],"author":"eeNews Europe","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eeNews Europe","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/"},"author":{"name":"eeNews Europe","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4"},"headline":"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019","datePublished":"2011-11-22T23:00:00+00:00","dateModified":"2011-11-22T23:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/"},"wordCount":252,"publisher":{"@id":"https:\/\/www.ecinews.fr\/fr\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/","url":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/","name":"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019 -","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/#website"},"datePublished":"2011-11-22T23:00:00+00:00","dateModified":"2011-11-22T23:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-dc-250-350-w-dans-un-format-de-3-x-5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Alimentations DC 250\/350 W dans un format de 3\u2019\u2019 x 5\u2019\u2019"}]},{"@type":"WebSite","@id":"https:\/\/www.ecinews.fr\/fr\/#website","url":"https:\/\/www.ecinews.fr\/fr\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.ecinews.fr\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ecinews.fr\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.ecinews.fr\/fr\/#organization","name":"EENewsEurope","url":"https:\/\/www.ecinews.fr\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4","name":"eeNews Europe","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22","url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","caption":"eeNews Europe"}}]}},"authors":[{"term_id":1149,"user_id":22,"is_guest":0,"slug":"eenews-europe","display_name":"eeNews Europe","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223019"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=223019"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/223019\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/223020"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=223019"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=223019"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=223019"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=223019"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=223019"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}