{"id":222167,"date":"2011-07-31T22:00:00","date_gmt":"2011-07-31T22:00:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/modules-pxi-dinsertion-de-defauts\/"},"modified":"2011-07-31T22:00:00","modified_gmt":"2011-07-31T22:00:00","slug":"modules-pxi-dinsertion-de-defauts","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/","title":{"rendered":"Modules PXI d&rsquo;insertion de d\u00e9fauts"},"content":{"rendered":"<p>Le 40-197 fournit jusqu&rsquo;&agrave; 34 canaux d&rsquo;insertion de d&eacute;fauts pouvant &ecirc;tre reli&eacute;s &agrave; n&rsquo;importe lequel des quatre bus de d&eacute;fauts, chacun ayant jusqu&rsquo;&agrave; deux&nbsp; conditions diff&eacute;rentes. Chaque canal d&rsquo;insertion de d&eacute;fauts peut commuter jusqu&rsquo;&agrave; 220VDC et 60W et supporter &agrave; chaud un courant de 2A sans interruption ou transporter jusqu&rsquo;&agrave; 6A pour des pics de mont&eacute;e de courants rapides sur de courtes dur&eacute;es. Le 40-197 &eacute;tablit un pont entre les modules d&rsquo;insertion de d&eacute;fauts simples de notre offre et ceux plus complexes de notre gamme d&rsquo;options FIBO &eacute;galement fournies par Pickering Interfaces.<br \/>\nLe 40-198 supporte jusqu&rsquo;&agrave; 20 canaux d&rsquo;insertion de d&eacute;fauts qui peuvent &ecirc;tre reli&eacute;s &agrave; un ou deux bus de d&eacute;fauts pour proposer les trois d&eacute;finitions optionnelles possibles. Avec des possibilit&eacute;s de commutation &agrave; chaud jusqu&rsquo;&agrave; 110VDC &amp; 150W, chaque canal peut supporter une commutation &agrave; chaud de 5A sans interruption ou transporter jusqu&rsquo;&agrave; 10A pour des pics de mont&eacute;e de courants rapides sur de courtes dur&eacute;es. Le 40-198 est con&ccedil;u pour combler le gap dans notre offre standard de solutions d&rsquo;insertion de d&eacute;fauts existantes entre 2A et 10A.<br \/>\nLes deux mod&egrave;les utilisent une conception de commutateur bas&eacute;e autour de relais &eacute;lectrom&eacute;caniques de haute qualit&eacute; et en plus d&rsquo;&ecirc;tre support&eacute; dans n&rsquo;importe quel ch&acirc;ssis PXI conforme au standard, ils peuvent &ecirc;tre &eacute;galement support&eacute;s dans les ch&acirc;ssis modulaires LXI de&nbsp; Pickering Interfaces.<\/p>\n<p><a href=\"http:\/\/www.pickeringtest.com\/\">www.pickeringtest.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pickering Interfaces \u00e9tend sa gamme de solutions PXI d&rsquo;insertion de d\u00e9fauts avec l&rsquo;introduction du 40-197 et 40-198. Les modules d&rsquo;insertion de d\u00e9fauts (FI) sont utilis\u00e9s dans un syst\u00e8me de Test Automatique pour simuler des conditions de panne communes telles qu&rsquo;une connexion ouverte, court-circuit \u00e0 la terre ou court-circuit \u00e0 d&rsquo;autres raccordements dans un dispositif sous test.<\/p>\n","protected":false},"author":22,"featured_media":222168,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1149],"class_list":["post-222167","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Modules PXI d&#039;insertion de d\u00e9fauts ...<\/title>\n<meta name=\"description\" content=\"Pickering Interfaces \u00e9tend sa gamme de solutions PXI d&#039;insertion de d\u00e9fauts avec l&#039;introduction du 40-197 et 40-198. Les modules d&#039;insertion de d\u00e9fauts...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/222167\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modules PXI d&#039;insertion de d\u00e9fauts\" \/>\n<meta property=\"og:description\" content=\"Pickering Interfaces \u00e9tend sa gamme de solutions PXI d&#039;insertion de d\u00e9fauts avec l&#039;introduction du 40-197 et 40-198. Les modules d&#039;insertion de d\u00e9fauts (FI) sont utilis\u00e9s dans un syst\u00e8me de Test Automatique pour simuler des conditions de panne communes telles qu&#039;une connexion ouverte, court-circuit \u00e0 la terre ou court-circuit \u00e0 d&#039;autres raccordements dans un dispositif sous test.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/222167\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2011-07-31T22:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci2203_pickering.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1114\" \/>\n\t<meta property=\"og:image:height\" content=\"779\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eeNews Europe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eeNews Europe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/\"},\"author\":{\"name\":\"eeNews Europe\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\"},\"headline\":\"Modules PXI d&rsquo;insertion de d\u00e9fauts\",\"datePublished\":\"2011-07-31T22:00:00+00:00\",\"dateModified\":\"2011-07-31T22:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/\"},\"wordCount\":304,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/\",\"name\":\"Modules PXI d'insertion de d\u00e9fauts -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2011-07-31T22:00:00+00:00\",\"dateModified\":\"2011-07-31T22:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Modules PXI d&rsquo;insertion de d\u00e9fauts\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\",\"name\":\"eeNews Europe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"caption\":\"eeNews Europe\"}}]}<\/script>","yoast_head_json":{"title":"Modules PXI d'insertion de d\u00e9fauts ...","description":"Pickering Interfaces \u00e9tend sa gamme de solutions PXI d'insertion de d\u00e9fauts avec l'introduction du 40-197 et 40-198. Les modules d'insertion de d\u00e9fauts...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/222167\/","og_locale":"fr_FR","og_type":"article","og_title":"Modules PXI d'insertion de d\u00e9fauts","og_description":"Pickering Interfaces \u00e9tend sa gamme de solutions PXI d'insertion de d\u00e9fauts avec l'introduction du 40-197 et 40-198. Les modules d'insertion de d\u00e9fauts (FI) sont utilis\u00e9s dans un syst\u00e8me de Test Automatique pour simuler des conditions de panne communes telles qu'une connexion ouverte, court-circuit \u00e0 la terre ou court-circuit \u00e0 d'autres raccordements dans un dispositif sous test.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/222167\/","og_site_name":"EENewsEurope","article_published_time":"2011-07-31T22:00:00+00:00","og_image":[{"width":1114,"height":779,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci2203_pickering.jpg","type":"image\/jpeg"}],"author":"eeNews Europe","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eeNews Europe","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/"},"author":{"name":"eeNews Europe","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4"},"headline":"Modules PXI d&rsquo;insertion de d\u00e9fauts","datePublished":"2011-07-31T22:00:00+00:00","dateModified":"2011-07-31T22:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/"},"wordCount":304,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/","url":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/","name":"Modules PXI d'insertion de d\u00e9fauts -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2011-07-31T22:00:00+00:00","dateModified":"2011-07-31T22:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/modules-pxi-dinsertion-de-defauts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Modules PXI d&rsquo;insertion de d\u00e9fauts"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4","name":"eeNews Europe","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22","url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","caption":"eeNews Europe"}}]}},"authors":[{"term_id":1149,"user_id":22,"is_guest":0,"slug":"eenews-europe","display_name":"eeNews Europe","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/222167"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=222167"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/222167\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/222168"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=222167"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=222167"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=222167"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=222167"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=222167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}