{"id":221228,"date":"2011-03-10T23:00:00","date_gmt":"2011-03-10T23:00:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/"},"modified":"2011-03-10T23:00:00","modified_gmt":"2011-03-10T23:00:00","slug":"controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/","title":{"rendered":"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s"},"content":{"rendered":"<p>Le contr&ocirc;leur PWM LM5045 offre toutes les caract&eacute;ristiques n&eacute;cessaires pour impl&eacute;menter un convertisseur de puissance &quot;pont complet &quot;, contr&ocirc;l&eacute; en mode courant ou en mode tension. Pour les applications n&eacute;cessitant une commutation &agrave; tension nulle&nbsp;pour r&eacute;duire au maximum les parasites &eacute;lectromagn&eacute;tiques dus au bruit de commutation, le contr&ocirc;leur PWM LM5046 contient tous les &eacute;l&eacute;ments n&eacute;cessaires &agrave; l&rsquo;implantation d&rsquo;une topologie pont complet &agrave; d&eacute;calage de phase. Propos&eacute;s en petits bo&icirc;tiers LLP de 5 mm x 5 mm x 0.8 mm optimis&eacute;s thermiquement ou en bo&icirc;tiers TSSOP de 4.4 mm x 9.7 mm x 0.9 mm, ces contr&ocirc;leurs pont complet s&rsquo;utilisent au primaire d&rsquo;un convertisseur CC-CC isol&eacute; avec une tension d&rsquo;entr&eacute;e jusqu&rsquo;&agrave; 100V. Ces contr&ocirc;leurs tr&egrave;s int&eacute;gr&eacute;s disposent de robustes drivers de commande 2A c&ocirc;t&eacute; haut et bas pour piloter les quatre MOSFET externes, en plus des signaux de commande destin&eacute;s aux MOSFET du redresseur synchrone au secondaire, et d&rsquo;un r&eacute;gulateur de d&eacute;marrage interne haute tension. Le d&eacute;marrage intelligent des redresseurs synchrones permet un d&eacute;marrage monotone du convertisseur de puissance, m&ecirc;me en pr&eacute;sence d&rsquo;une charge pr&eacute;-polaris&eacute;e. Les signaux de commande du redresseur synchrone autorisent des temps morts de fronts montants\/descendants ind&eacute;pendants et programmables entre les signaux de commande des MOSFET primaires et secondaires de transistor MOSFET pour optimiser le rendement, et les signaux SR sont limit&eacute;s &agrave; 5V pour permettre l&rsquo;utilisation avec des isolateurs num&eacute;riques. Les fonctionnalit&eacute;s suppl&eacute;mentaires sont notamment une double protection contre les surintensit&eacute;s int&eacute;grant &agrave; la fois une limitation de courant cycle par cycle et red&eacute;marrage en mode &quot;hiccup&quot;, le d&eacute;marrage progressif programmable; des fonctions de synchronisation &agrave; la fois pour les redresseurs primaires et les redresseurs synchrones, une ligne UVLO et OVP programmable, un oscillateur 2 MHz synchronisable, et une fonction de protection arr&ecirc;t thermique.<\/p>\n<p><a target=\"_blank\" href=\"http:\/\/www.national.com\/pf\/LM\/LM5045.html\" rel=\"noopener\">www.national.com\/pf\/LM\/LM5045.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>National Semiconductor a pr\u00e9sent\u00e9 les premiers contr\u00f4leurs PWM (modulation de largeur d&rsquo;impulsions) du march\u00e9 int\u00e9grant leurs quatre drivers de MOSFET de pont aux primaires. Les LM5045 et LM5046 sont bien adapt\u00e9s pour fournir un rendement et une densit\u00e9 de puissance sup\u00e9rieurs dans les modules \u00ab\u00a0quart de brique\u00a0\u00bb ou \u00ab\u00a0huiti\u00e8me de brique\u00a0\u00bb utilis\u00e9s dans certains applications d&rsquo;infrastructure de transmissions haute tension. Membres de la famille de produits \u00e0 rendement optimis\u00e9 PowerWise de National, les contr\u00f4leurs PWM LM5045 et LM5046 facilitent la conception de convertisseurs \u00ab\u00a0full-bridge\u00a0\u00bb dans les alimentations de petit format, en r\u00e9duisant le nombre de composants de puissance externes n\u00e9cessaire avec les solutions \u00ab\u00a0pont complet\u00a0\u00bb existantes.<\/p>\n","protected":false},"author":22,"featured_media":221229,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1149],"class_list":["post-221228","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s ...<\/title>\n<meta name=\"description\" content=\"National Semiconductor a pr\u00e9sent\u00e9 les premiers contr\u00f4leurs PWM (modulation de largeur d&#039;impulsions) du march\u00e9 int\u00e9grant leurs quatre drivers de MOSFET...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/221228\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s\" \/>\n<meta property=\"og:description\" content=\"National Semiconductor a pr\u00e9sent\u00e9 les premiers contr\u00f4leurs PWM (modulation de largeur d&#039;impulsions) du march\u00e9 int\u00e9grant leurs quatre drivers de MOSFET de pont aux primaires. Les LM5045 et LM5046 sont bien adapt\u00e9s pour fournir un rendement et une densit\u00e9 de puissance sup\u00e9rieurs dans les modules &quot;quart de brique&quot; ou &quot;huiti\u00e8me de brique&quot; utilis\u00e9s dans certains applications d&#039;infrastructure de transmissions haute tension. Membres de la famille de produits \u00e0 rendement optimis\u00e9 PowerWise de National, les contr\u00f4leurs PWM LM5045 et LM5046 facilitent la conception de convertisseurs &quot;full-bridge&quot; dans les alimentations de petit format, en r\u00e9duisant le nombre de composants de puissance externes n\u00e9cessaire avec les solutions &quot;pont complet&quot; existantes.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/221228\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2011-03-10T23:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci1997_ns.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1249\" \/>\n\t<meta property=\"og:image:height\" content=\"833\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eeNews Europe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eeNews Europe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/\"},\"author\":{\"name\":\"eeNews Europe\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\"},\"headline\":\"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s\",\"datePublished\":\"2011-03-10T23:00:00+00:00\",\"dateModified\":\"2011-03-10T23:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/\"},\"wordCount\":402,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/\",\"name\":\"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2011-03-10T23:00:00+00:00\",\"dateModified\":\"2011-03-10T23:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\",\"name\":\"eeNews Europe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"caption\":\"eeNews Europe\"}}]}<\/script>","yoast_head_json":{"title":"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s ...","description":"National Semiconductor a pr\u00e9sent\u00e9 les premiers contr\u00f4leurs PWM (modulation de largeur d'impulsions) du march\u00e9 int\u00e9grant leurs quatre drivers de MOSFET...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/221228\/","og_locale":"fr_FR","og_type":"article","og_title":"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s","og_description":"National Semiconductor a pr\u00e9sent\u00e9 les premiers contr\u00f4leurs PWM (modulation de largeur d'impulsions) du march\u00e9 int\u00e9grant leurs quatre drivers de MOSFET de pont aux primaires. Les LM5045 et LM5046 sont bien adapt\u00e9s pour fournir un rendement et une densit\u00e9 de puissance sup\u00e9rieurs dans les modules \"quart de brique\" ou \"huiti\u00e8me de brique\" utilis\u00e9s dans certains applications d'infrastructure de transmissions haute tension. Membres de la famille de produits \u00e0 rendement optimis\u00e9 PowerWise de National, les contr\u00f4leurs PWM LM5045 et LM5046 facilitent la conception de convertisseurs \"full-bridge\" dans les alimentations de petit format, en r\u00e9duisant le nombre de composants de puissance externes n\u00e9cessaire avec les solutions \"pont complet\" existantes.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/221228\/","og_site_name":"EENewsEurope","article_published_time":"2011-03-10T23:00:00+00:00","og_image":[{"width":1249,"height":833,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/import\/eci1997_ns.jpg","type":"image\/jpeg"}],"author":"eeNews Europe","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eeNews Europe","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/"},"author":{"name":"eeNews Europe","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4"},"headline":"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s","datePublished":"2011-03-10T23:00:00+00:00","dateModified":"2011-03-10T23:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/"},"wordCount":402,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/","url":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/","name":"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2011-03-10T23:00:00+00:00","dateModified":"2011-03-10T23:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/controleurs-pwm-pont-complet-a-drivers-de-mosfet-integres\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Contr\u00f4leurs PWM pont complet \u00e0 drivers de MOSFET int\u00e9gr\u00e9s"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4","name":"eeNews Europe","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22","url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","caption":"eeNews Europe"}}]}},"authors":[{"term_id":1149,"user_id":22,"is_guest":0,"slug":"eenews-europe","display_name":"eeNews Europe","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/221228"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=221228"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/221228\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/221229"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=221228"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=221228"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=221228"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=221228"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=221228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}