{"id":218508,"date":"2016-03-09T07:02:00","date_gmt":"2016-03-09T07:02:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/"},"modified":"2016-03-09T07:02:00","modified_gmt":"2016-03-09T07:02:00","slug":"transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/","title":{"rendered":"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s"},"content":{"rendered":"<p>Les concepteurs de mat\u00e9riel d&rsquo;automatisation industrielle ont besoin de solutions offrant, \u00e0 la fois, souplesse et rendement \u00e9lev\u00e9. L&rsquo;int\u00e9gration \u00e9lev\u00e9e de la famille de transpondeurs RS-485 \u00e0 transformateur driver et r\u00e9gulateur LDO int\u00e9gr\u00e9s, simplifie la conception de circuits avec puissance et donn\u00e9es isol\u00e9es. Le mod\u00e8le RS-485\/PROFIBUS DP isol\u00e9 MAX14943, tout comme le MAX14949, offrent jusqu&rsquo;\u00e0 80% de rendement avec une charge de 150 mA.<\/p>\n<p>Propos\u00e9e en versions half-duplex ou full-duplex, cette famille de transpondeurs RS-485 supporte un isolement jusqu&rsquo;\u00e0 5 kVeff, une protection ESD de \u00b135 kV HBM et assure des communications robustes jusqu&rsquo;\u00e0 25 Mbits\/s.<\/p>\n<p>Ces \u00e9metteurs-r\u00e9cepteurs sont particuli\u00e8rement bien adapt\u00e9s pour l&rsquo;automatisation industrielle, les contr\u00f4leurs programmables PLC, les syst\u00e8mes de chauffage, ventilation et climatisation HVAC et les compteurs \u00e9lectriques.<\/p>\n<p>\u00ab\u00a0Nos transpondeurs \u00e0 niveau de protection ESD \u00e9lev\u00e9, associ\u00e9s \u00e0 la technologie d&rsquo;isolement num\u00e9rique robuste de Maxim, constituent la solution RS-485 isol\u00e9e la plus robuste du march\u00e9, \u00a0\u00bb d\u00e9clare Timothy Leung, Directeur de Division Senior chez Maxim Integrated. \u00ab\u00a0Nous avons int\u00e9gr\u00e9 un LDO pour r\u00e9guler l&rsquo;alimentation isol\u00e9e et offrir aux concepteurs une solution plus compacte avec un co\u00fbt syst\u00e8me inf\u00e9rieur.\u00a0\u00bb<\/p>\n<p>\u00ab\u00a0Un rendement \u00e9lev\u00e9 et des communications robustes sont essentiels pour concevoir des \u00e9quipements d&rsquo;automatisation industrielle,\u00a0\u00bb affirme Susie Inouye, Directrice de Recherches chez Databeans. \u00ab\u00a0La famille de transpondeurs de Maxim constitue la solution id\u00e9ale pour les concepteurs \u00e0 la recherche de cela.\u00a0\u00bb<\/p>\n<p>Propos\u00e9s en bo\u00eetier W-SOIC 16 de seulement 11 x 11 mm, ces transpondeurs sont sp\u00e9cifi\u00e9s sur la gamme de temp\u00e9ratures op\u00e9rationnelles allant de -40 \u00b0C \u00e0 +105 \u00b0C. Ils sont accompagn\u00e9s des kits d\u2019\u00e9valuation MAX148X2_EV_KIT et MAX149X2_EV_KIT pour faciliter les d\u00e9veloppements.<\/p>\n<\/p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les d\u00e9veloppeurs peuvent profiter d&rsquo;une conception facilit\u00e9e, d&rsquo;un rendement \u00e9lev\u00e9 et de transmissions robustes pour leurs applications d&rsquo;automatisation industrielle gr\u00e2ce \u00e0 la famille MAX14853\/MAX14855 et MAX14943\/MAX14949 de transpondeurs RS-485 \u00e0 haut niveau d&rsquo;int\u00e9gration de Maxim Integrated Products. <\/p>\n","protected":false},"author":22,"featured_media":218509,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[903],"domains":[47],"ppma_author":[1149],"class_list":["post-218508","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","tag-interconnect-cables-fr","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO in...<\/title>\n<meta name=\"description\" content=\"Les d\u00e9veloppeurs peuvent profiter d&#039;une conception facilit\u00e9e, d&#039;un rendement \u00e9lev\u00e9 et de transmissions robustes pour leurs applications d&#039;automatisation...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/218508\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s\" \/>\n<meta property=\"og:description\" content=\"Les d\u00e9veloppeurs peuvent profiter d&#039;une conception facilit\u00e9e, d&#039;un rendement \u00e9lev\u00e9 et de transmissions robustes pour leurs applications d&#039;automatisation industrielle gr\u00e2ce \u00e0 la famille MAX14853\/MAX14855 et MAX14943\/MAX14949 de transpondeurs RS-485 \u00e0 haut niveau d&#039;int\u00e9gration de Maxim Integrated Products.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/218508\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-09T07:02:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7712_maxim_max14853_55_max14943_49_image_r.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1370\" \/>\n\t<meta property=\"og:image:height\" content=\"1038\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eeNews Europe\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eeNews Europe\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/\"},\"author\":{\"name\":\"eeNews Europe\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\"},\"headline\":\"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s\",\"datePublished\":\"2016-03-09T07:02:00+00:00\",\"dateModified\":\"2016-03-09T07:02:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/\"},\"wordCount\":307,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"keywords\":[\"Interconnect &amp; cables\"],\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/\",\"name\":\"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2016-03-09T07:02:00+00:00\",\"dateModified\":\"2016-03-09T07:02:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cdn.eenewseurope.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4\",\"name\":\"eeNews Europe\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g\",\"caption\":\"eeNews Europe\"}}]}<\/script>","yoast_head_json":{"title":"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO in...","description":"Les d\u00e9veloppeurs peuvent profiter d'une conception facilit\u00e9e, d'un rendement \u00e9lev\u00e9 et de transmissions robustes pour leurs applications d'automatisation...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/218508\/","og_locale":"fr_FR","og_type":"article","og_title":"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s","og_description":"Les d\u00e9veloppeurs peuvent profiter d'une conception facilit\u00e9e, d'un rendement \u00e9lev\u00e9 et de transmissions robustes pour leurs applications d'automatisation industrielle gr\u00e2ce \u00e0 la famille MAX14853\/MAX14855 et MAX14943\/MAX14949 de transpondeurs RS-485 \u00e0 haut niveau d'int\u00e9gration de Maxim Integrated Products.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/218508\/","og_site_name":"EENewsEurope","article_published_time":"2016-03-09T07:02:00+00:00","og_image":[{"width":1370,"height":1038,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci7712_maxim_max14853_55_max14943_49_image_r.jpg","type":"image\/jpeg"}],"author":"eeNews Europe","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eeNews Europe","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/"},"author":{"name":"eeNews Europe","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4"},"headline":"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s","datePublished":"2016-03-09T07:02:00+00:00","dateModified":"2016-03-09T07:02:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/"},"wordCount":307,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"keywords":["Interconnect &amp; cables"],"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/","url":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/","name":"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2016-03-09T07:02:00+00:00","dateModified":"2016-03-09T07:02:00+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/transpondeurs-rs-485-isoles-a-transformateur-driver-et-ldo-integres\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cdn.eenewseurope.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Transpondeurs RS-485 isol\u00e9s \u00e0 transformateur driver et LDO int\u00e9gr\u00e9s"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/9eff4051fa9dac8230052de45e32b0f4","name":"eeNews Europe","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/fae8f0cb15861c4ae0ed4872e2c9fc22","url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","caption":"eeNews Europe"}}]}},"authors":[{"term_id":1149,"user_id":22,"is_guest":0,"slug":"eenews-europe","display_name":"eeNews Europe","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/5081509054e28b04ecd976976e723ce0?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/218508"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=218508"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/218508\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/218509"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=218508"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=218508"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=218508"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=218508"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=218508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}