{"id":181800,"date":"2017-02-22T00:00:00","date_gmt":"2017-02-22T00:00:00","guid":{"rendered":"https:\/\/eenewseurope.artwhere.co\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/"},"modified":"2017-02-22T00:00:00","modified_gmt":"2017-02-22T00:00:00","slug":"alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/","title":{"rendered":"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II"},"content":{"rendered":"<p>La s\u00e9rie se d\u00e9cline dans les 6 tensions de sortie courantes&nbsp;de 12, 19, 24, 28, 48 et 54&nbsp;VDC et peut fonctionner sur une plage d\u2019entr\u00e9e comprise entre 90 et 264&nbsp;VAC. En entr\u00e9e, elle offre un connecteur standard CEI 60320-C14 \u00e0 3 broches ou 60320-C18 \u00e0 2&nbsp;broches. Le c\u00e2ble de sortie se termine par un connecteur Molex Mini-Fit \u00e0 10 broches, d\u2019autres types de connecteurs pouvant \u00eatre fournis sur demande.<\/p>\n<p>L\u2019ensemble des mod\u00e8les pr\u00e9sente un niveau de rendement moyen sup\u00e9rieur \u00e0 88&nbsp;% et une consommation \u00e9lectrique \u00e0 vide inf\u00e9rieure \u00e0 0,5&nbsp;W, ce qui satisfait aux exigences de rendement de niveau VI du DOE. Le bo\u00eetier de cet adaptateur est herm\u00e9tique et ne n\u00e9cessite pas de ventilation. Il mesure 222&nbsp;mm de long, 112&nbsp;mm de large et 45&nbsp;mm de haut.<\/p>\n<p>Certifi\u00e9e conforme aux normes CEI\/ES\/CSA\/EN 60601-1 et CEI\/UL\/CSA\/EN 60950-1, cette s\u00e9rie porte le marquage CE attestant de son respect des directives \u00ab\u00a0basse tension\u00a0\u00bb, CEM et RoHS2. Le niveau de conformit\u00e9 aux normes de s\u00e9curit\u00e9 m\u00e9dicales a \u00e9t\u00e9 \u00e9galement renforc\u00e9 en proposant jusqu\u2019\u00e0 2&nbsp;MoPP (moyens de protection des patients) entre l\u2019entr\u00e9e et la sortie. Le courant de contact est inf\u00e9rieur \u00e0 100&nbsp;\u00b5A et les mod\u00e8les de classe I sont adapt\u00e9s aux mat\u00e9riels classifi\u00e9s BF. Tous les mod\u00e8les sont conformes aux normes NF&nbsp;EN 55011-B, NF&nbsp;EN 55022-B, NF EN 55024-B, FCC-B et NF&nbsp;EN 60601-1-2 Ed4:2014 CEM.<\/p>\n<p>Ces alimentations sont \u00e9galement propos\u00e9es avec les certifications de s\u00e9curit\u00e9 ITE pour les \u00e9quipements industriels, de test et de mesure.<\/p>\n<p><a href=\"http:\/\/www.fr.tdk-lambda.com\/dtm\" target=\"_blank\" rel=\"noopener\">www.fr.tdk-lambda.com\/dtm<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Conformes aux derni\u00e8res normes m\u00e9dicales CEI 60601-1 et 60601-1-2, les alimentations externes 300 W s\u00e9rie DTM300 de TDK Lambda sont dot\u00e9es d\u2019une isolation de 4000 VAC entre l\u2019entr\u00e9e et la sortie et propos\u00e9es avec une entr\u00e9e de classe I ou de classe II. Elles sont destin\u00e9es \u00e0 l\u2019alimentation de toute une gamme d\u2019instruments hospitaliers, dentaires et m\u00e9dicaux de surveillance, d\u2019imagerie et de diagnostic.<\/p>\n","protected":false},"author":9,"featured_media":181801,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[909],"domains":[47],"ppma_author":[1141],"class_list":["post-181800","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","tag-batteries-power-supplies-fr","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de cla...<\/title>\n<meta name=\"description\" content=\"Conformes aux derni\u00e8res normes m\u00e9dicales CEI 60601-1 et 60601-1-2, les alimentations externes 300 W s\u00e9rie DTM300 de TDK Lambda sont dot\u00e9es d\u2019une...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/181800\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II\" \/>\n<meta property=\"og:description\" content=\"Conformes aux derni\u00e8res normes m\u00e9dicales CEI 60601-1 et 60601-1-2, les alimentations externes 300 W s\u00e9rie DTM300 de TDK Lambda sont dot\u00e9es d\u2019une isolation de 4000 VAC entre l\u2019entr\u00e9e et la sortie et propos\u00e9es avec une entr\u00e9e de classe I ou de classe II. Elles sont destin\u00e9es \u00e0 l\u2019alimentation de toute une gamme d\u2019instruments hospitaliers, dentaires et m\u00e9dicaux de surveillance, d\u2019imagerie et de diagnostic.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/181800\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-22T00:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci8373_tdk_la008115_-_dtm300_r.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2100\" \/>\n\t<meta property=\"og:image:height\" content=\"1355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\"},\"headline\":\"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II\",\"datePublished\":\"2017-02-22T00:00:00+00:00\",\"dateModified\":\"2017-02-22T00:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/\"},\"wordCount\":297,\"publisher\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#organization\"},\"keywords\":[\"Batteries \/ Power Supplies\"],\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/\",\"name\":\"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II -\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#website\"},\"datePublished\":\"2017-02-22T00:00:00+00:00\",\"dateModified\":\"2017-02-22T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#website\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ecinews.fr\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de cla...","description":"Conformes aux derni\u00e8res normes m\u00e9dicales CEI 60601-1 et 60601-1-2, les alimentations externes 300 W s\u00e9rie DTM300 de TDK Lambda sont dot\u00e9es d\u2019une...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/181800\/","og_locale":"fr_FR","og_type":"article","og_title":"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II","og_description":"Conformes aux derni\u00e8res normes m\u00e9dicales CEI 60601-1 et 60601-1-2, les alimentations externes 300 W s\u00e9rie DTM300 de TDK Lambda sont dot\u00e9es d\u2019une isolation de 4000 VAC entre l\u2019entr\u00e9e et la sortie et propos\u00e9es avec une entr\u00e9e de classe I ou de classe II. Elles sont destin\u00e9es \u00e0 l\u2019alimentation de toute une gamme d\u2019instruments hospitaliers, dentaires et m\u00e9dicaux de surveillance, d\u2019imagerie et de diagnostic.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/181800\/","og_site_name":"EENewsEurope","article_published_time":"2017-02-22T00:00:00+00:00","og_image":[{"width":2100,"height":1355,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci8373_tdk_la008115_-_dtm300_r.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf"},"headline":"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II","datePublished":"2017-02-22T00:00:00+00:00","dateModified":"2017-02-22T00:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/"},"wordCount":297,"publisher":{"@id":"https:\/\/www.ecinews.fr\/fr\/#organization"},"keywords":["Batteries \/ Power Supplies"],"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/","url":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/","name":"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II -","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/#website"},"datePublished":"2017-02-22T00:00:00+00:00","dateModified":"2017-02-22T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-medicales-300-w-de-niveau-iv-avec-entree-de-classe-i-ou-ii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Alimentations m\u00e9dicales 300 W de niveau IV avec entr\u00e9e de classe I ou II"}]},{"@type":"WebSite","@id":"https:\/\/www.ecinews.fr\/fr\/#website","url":"https:\/\/www.ecinews.fr\/fr\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.ecinews.fr\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ecinews.fr\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.ecinews.fr\/fr\/#organization","name":"EENewsEurope","url":"https:\/\/www.ecinews.fr\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ecinews.fr\/fr\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364","url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/181800"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=181800"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/181800\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/181801"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=181800"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=181800"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=181800"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=181800"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=181800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}