{"id":14131,"date":"2021-04-18T19:23:35","date_gmt":"2021-04-18T19:23:35","guid":{"rendered":"https:\/\/\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/"},"modified":"2021-04-18T19:23:35","modified_gmt":"2021-04-18T19:23:35","slug":"solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/","title":{"rendered":"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1"},"content":{"rendered":"<p>Les syst\u00e8mes de d\u00e9tection exploitant des cam\u00e9ras embarqu\u00e9es autour du v\u00e9hicule, les unit\u00e9s 5G de contr\u00f4le t\u00e9l\u00e9matique (TCU) et l\u2019infrastructure r\u00e9seau des contr\u00f4leurs multi-domaine exigent des d\u00e9bits de donn\u00e9es toujours plus \u00e9lev\u00e9s. La norme Ethernet MultiGBASE-T1 r\u00e9pond \u00e0 cette attente en offrant des d\u00e9bits atteignant 2,5G, 5G et 10G. Par rapport \u00e0 la technologie 1000BASE-T1, le standard MultiGBASE-T1 met en \u0153uvre une technique de modulation d&rsquo;impulsions en amplitude \u00e0 4 niveaux (PAM4) dont les d\u00e9bits de symboles atteignent 1,4 GHz, 2,8 GHz et 5,6 GHz. La sp\u00e9cification de test de conformit\u00e9 PMA concernant cette norme, \u00e9tablie par le comit\u00e9 technique TC15 de l&rsquo;Open Alliance, est encore \u00e0 l&rsquo;\u00e9tat de projet.<br \/>\nDot\u00e9s de la nouvelle option K88, les oscilloscopes R&amp;S RTO et R&amp;S RTP constituent d\u00e9sormais une solution pleinement adapt\u00e9e au test de conformit\u00e9 d&rsquo;\u00e9metteur MultiGBASE-T1 selon la sp\u00e9cification IEEE802.3ch relative \u00e0 la couche physique (PHY, couche 1). Ils proposent une interface utilisateur moderne et ergonomique qui guide l\u2019utilisateur dans le d\u00e9roulement des tests et d\u00e9livrent un rapport de test tr\u00e8s complet.<br \/>\nRohde &amp; Schwarz propose une gamme compl\u00e8te de solutions de test de conformit\u00e9 Ethernet automobile qui comprend notamment l\u2019analyseur de r\u00e9seau vectoriel R&amp;S ZND qui peut \u00eatre utilis\u00e9 pour r\u00e9aliser des mesures de pertes par r\u00e9flexion MDI. Le logiciel de test R&amp;S ScopeSuite permet d\u2019automatiser le contr\u00f4le des instruments de mesure ainsi que les t\u00e2ches de traitement des r\u00e9sultats et d\u2019\u00e9dition de rapports. Un outil d\u2019assistance guide pas \u00e0 pas l&rsquo;utilisateur par des instructions illustr\u00e9es durant la proc\u00e9dure de test. L\u2019automatisation des tests assurent leur rapidit\u00e9 et leur fiabilit\u00e9 en minimisant les risques d&rsquo;erreurs humaines. Les r\u00e9sultats du test sont document\u00e9s dans un rapport configurable par l\u2019utilisateur. R&amp;S ScopeSuite est une application logicielle autonome qui peut aussi bien \u00eatre ex\u00e9cut\u00e9e sur l&rsquo;oscilloscope que sur un PC distinct.<br \/>\n<a href=\"http:\/\/www.rohde-schwarz.com\/_231834.html\">www.rohde-schwarz.com\/_231834.html<\/a><\/p>\n<p><strong>A lire \u00e9galement :<\/strong><br \/>\nhttps:\/\/www.ecinews.fr\/news\/sourcemetres-hautes-performances<\/p>\n<p>https:\/\/www.ecinews.fr\/news\/sondes-pour-mesures-grande-vitesse-et-haute-precision-des-puissances-rf-jusqua-67-ghz<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Avec la nouvelle option K88, les oscilloscopes des gammes R&amp;S RTO et R&amp;S RTP de Rohde &amp; Schwarz peuvent r\u00e9aliser des tests de conformit\u00e9 selon les exigences de la prochaine \u00e9volution de la norme Ethernet automobile. La nouvelle norme IEEE 802.3ch r\u00e9pond aux besoins des r\u00e9seaux de transfert de donn\u00e9es haut d\u00e9bit dans un v\u00e9hicule. Avec le lancement de l\u2019option logicielle K88, Rohde &amp; Schwarz poursuit son engagement sans faille dans le domaine du test et de mesures pour l&rsquo;Ethernet automobile.<\/p>\n","protected":false},"author":9,"featured_media":14132,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1141],"class_list":["post-14131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet a...<\/title>\n<meta name=\"description\" content=\"Avec la nouvelle option K88, les oscilloscopes des gammes R&amp;S RTO et R&amp;S RTP de Rohde &amp; Schwarz peuvent r\u00e9aliser des tests de conformit\u00e9 selon...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/14131\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1\" \/>\n<meta property=\"og:description\" content=\"Avec la nouvelle option K88, les oscilloscopes des gammes R&amp;S RTO et R&amp;S RTP de Rohde &amp; Schwarz peuvent r\u00e9aliser des tests de conformit\u00e9 selon les exigences de la prochaine \u00e9volution de la norme Ethernet automobile. La nouvelle norme IEEE 802.3ch r\u00e9pond aux besoins des r\u00e9seaux de transfert de donn\u00e9es haut d\u00e9bit dans un v\u00e9hicule. Avec le lancement de l\u2019option logicielle K88, Rohde &amp; Schwarz poursuit son engagement sans faille dans le domaine du test et de mesures pour l&#039;Ethernet automobile.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/14131\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2021-04-18T19:23:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci9197_rohde_schwarz-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\"},\"headline\":\"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1\",\"datePublished\":\"2021-04-18T19:23:35+00:00\",\"dateModified\":\"2021-04-18T19:23:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/\"},\"wordCount\":384,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/\",\"name\":\"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1 -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2021-04-18T19:23:35+00:00\",\"dateModified\":\"2021-04-18T19:23:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet a...","description":"Avec la nouvelle option K88, les oscilloscopes des gammes R&amp;S RTO et R&amp;S RTP de Rohde &amp; Schwarz peuvent r\u00e9aliser des tests de conformit\u00e9 selon...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/14131\/","og_locale":"fr_FR","og_type":"article","og_title":"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1","og_description":"Avec la nouvelle option K88, les oscilloscopes des gammes R&amp;S RTO et R&amp;S RTP de Rohde &amp; Schwarz peuvent r\u00e9aliser des tests de conformit\u00e9 selon les exigences de la prochaine \u00e9volution de la norme Ethernet automobile. La nouvelle norme IEEE 802.3ch r\u00e9pond aux besoins des r\u00e9seaux de transfert de donn\u00e9es haut d\u00e9bit dans un v\u00e9hicule. Avec le lancement de l\u2019option logicielle K88, Rohde &amp; Schwarz poursuit son engagement sans faille dans le domaine du test et de mesures pour l'Ethernet automobile.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/14131\/","og_site_name":"EENewsEurope","article_published_time":"2021-04-18T19:23:35+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci9197_rohde_schwarz-scaled.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf"},"headline":"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1","datePublished":"2021-04-18T19:23:35+00:00","dateModified":"2021-04-18T19:23:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/"},"wordCount":384,"commentCount":0,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/","url":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/","name":"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1 -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2021-04-18T19:23:35+00:00","dateModified":"2021-04-18T19:23:35+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/solution-de-test-de-conformite-a-la-nouvelle-norme-ethernet-automobile-ieee-802-3ch-multigbase-t1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Solution de test de conformit\u00e9 \u00e0 la nouvelle norme Ethernet automobile IEEE 802.3ch MultiGBASE-T1"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364","url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/14131"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=14131"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/14131\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/14132"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=14131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=14131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=14131"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=14131"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=14131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}