{"id":11665,"date":"2021-05-26T20:00:27","date_gmt":"2021-05-26T20:00:27","guid":{"rendered":"https:\/\/\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/"},"modified":"2021-05-26T20:00:27","modified_gmt":"2021-05-26T20:00:27","slug":"les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/","title":{"rendered":"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision"},"content":{"rendered":"<p>La solution de r\u00e9gulation lin\u00e9aire des sorties, mise en \u0153uvre par Rohde &amp; Schwarz, am\u00e9liore consid\u00e9rablement les performances des alimentations R&amp;S NGA100 par rapport aux techniques \u00e0 d\u00e9coupage fr\u00e9quemment exploit\u00e9es par les alimentations de laboratoire traditionnelles. Il en r\u00e9sulte une am\u00e9lioration de la pr\u00e9cision qui permet aux ing\u00e9nieurs d\u2019avoir l\u2019assurance de fournir l\u2019exact niveau de puissance n\u00e9cessaire \u00e0 leur application de test sans utiliser de multim\u00e8tre. La r\u00e9solution standard de 1 mV \/ 100 \u00b5A est ainsi consid\u00e9rablement am\u00e9lior\u00e9e pour la g\u00e9n\u00e9ration de courants inf\u00e9rieurs \u00e0 200 mA. Cette r\u00e9solution, qui atteint d\u00e9sormais 1 \u00b5A, est parfaitement adapt\u00e9e aux faibles niveaux de courant qui sont notamment n\u00e9cessaires au test en mode veille d\u2019\u00e9quipements IoT. L\u00b4alimentation R&amp;S NGA100 offre \u00e9galement une excellente r\u00e9gulation de charge pour les ph\u00e9nom\u00e8nes transitoires comme les appels de courant et de puissance induits.<\/p>\n<p>De nombreuses alimentations de laboratoire ne d\u00e9livrent leur puissance maximale seulement sur une plage tr\u00e8s limit\u00e9e de tension et de courant. Gr\u00e2ce \u00e0 la technologie FlexPower, mise en \u0153uvre par Rohde &amp; Schwarz, les alimentations R&amp;S NGA100 peuvent fournir leur puissance maximale dans une grande vari\u00e9t\u00e9 de configurations. Une seule alimentation peut ainsi prendre en charge une large diversit\u00e9 d\u2019applications. Quelle que soit l&rsquo;application, la clart\u00e9 de l\u2019\u00e9cran et l\u2019ergonomie de l\u2019interface d\u2019utilisation permettent aux utilisateurs de tirer le meilleur parti de fonctionnalit\u00e9s avanc\u00e9es telles que des calculs statistiques instantan\u00e9es (valeurs maximales et minimales de la puissance, de la tension et du courant), dont les valeurs sont directement affich\u00e9es \u00e0 l&rsquo;\u00e9cran.<\/p>\n<p>Les alimentations de laboratoire R&amp;S NGA100 se distinguent de leurs homologues du march\u00e9 par d\u2019autres caract\u00e9ristiques, comme par exemple l&rsquo;enregistrement, \u00e0 une cadence pouvant atteindre jusqu&rsquo;\u00e0 10 \u00e9chantillons par seconde, des valeurs de tension et de courant pour leur analyse ult\u00e9rieure. L&rsquo;exportation des donn\u00e9es et le contr\u00f4le \u00e0 distance de l\u2019alimentation peuvent s\u2019effectuer via leurs ports Ethernet et USB int\u00e9gr\u00e9s en standard. Une interface WLAN et des entr\u00e9es\/sorties num\u00e9riques de d\u00e9clenchement externe sont \u00e9galement propos\u00e9es en option. Les utilisateurs peuvent configurer des s\u00e9quences de g\u00e9n\u00e9ration de tension\/courant avec des intervalles allant jusqu&rsquo;\u00e0 10 ms. Les signaux g\u00e9n\u00e9r\u00e9s par l\u2019alimentation pr\u00e9sentent une faible distorsion et un faible niveau de bruit, tandis que la fonction de t\u00e9l\u00e9d\u00e9tection de l&rsquo;instrument compense les pertes li\u00e9es au c\u00e2blage entre les bornes de sortie de l&rsquo;alimentation et l\u2019appareil sous test qui est ainsi aliment\u00e9 au niveau de ses bornes d\u2019entr\u00e9e par l\u2019exacte puissance souhait\u00e9e.<\/p>\n<p><a href=\"http:\/\/www.rohde-schwarz.com\/fr\">www.rohde-schwarz.com\/fr<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rohde &amp; Schwarz continue d\u2019\u00e9toffer sa gamme d&rsquo;alimentations de laboratoire avec la famille R&amp;S NGA100. Elle est compos\u00e9e de quatre mod\u00e8les, dot\u00e9s d\u2019une ou deux sorties d\u00e9livrant pour chacune des voies des tensions et des courants allant jusqu&rsquo;\u00e0 35 V\/ 6 A ou 100 V \/ 2 A. Les mod\u00e8les mono-voie fournissent une puissance allant jusqu\u2019\u00e0 40 W, alors que celle des mod\u00e8les deux voies atteint 80 W. Les sorties des alimentations double voies peuvent \u00eatre combin\u00e9es pour d\u00e9livrer des tensions ou des courants jusqu&rsquo;\u00e0 200 V ou 12 A.<\/p>\n","protected":false},"author":9,"featured_media":11666,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1141],"class_list":["post-11665","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent...<\/title>\n<meta name=\"description\" content=\"Rohde &amp; Schwarz continue d\u2019\u00e9toffer sa gamme d&#039;alimentations de laboratoire avec la famille R&amp;S NGA100. Elle est compos\u00e9e de quatre mod\u00e8les,...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/11665\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision\" \/>\n<meta property=\"og:description\" content=\"Rohde &amp; Schwarz continue d\u2019\u00e9toffer sa gamme d&#039;alimentations de laboratoire avec la famille R&amp;S NGA100. Elle est compos\u00e9e de quatre mod\u00e8les, dot\u00e9s d\u2019une ou deux sorties d\u00e9livrant pour chacune des voies des tensions et des courants allant jusqu&#039;\u00e0 35 V\/ 6 A ou 100 V \/ 2 A. Les mod\u00e8les mono-voie fournissent une puissance allant jusqu\u2019\u00e0 40 W, alors que celle des mod\u00e8les deux voies atteint 80 W. Les sorties des alimentations double voies peuvent \u00eatre combin\u00e9es pour d\u00e9livrer des tensions ou des courants jusqu&#039;\u00e0 200 V ou 12 A.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/11665\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2021-05-26T20:00:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci9257_rohde_schwarz.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"911\" \/>\n\t<meta property=\"og:image:height\" content=\"733\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\"},\"headline\":\"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision\",\"datePublished\":\"2021-05-26T20:00:27+00:00\",\"dateModified\":\"2021-05-26T20:00:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/\"},\"wordCount\":494,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/\",\"name\":\"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2021-05-26T20:00:27+00:00\",\"dateModified\":\"2021-05-26T20:00:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"Les alimentations de laboratoire de la gamme R&S NGA100 gagnent...","description":"Rohde &amp; Schwarz continue d\u2019\u00e9toffer sa gamme d'alimentations de laboratoire avec la famille R&amp;S NGA100. Elle est compos\u00e9e de quatre mod\u00e8les,...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/11665\/","og_locale":"fr_FR","og_type":"article","og_title":"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision","og_description":"Rohde &amp; Schwarz continue d\u2019\u00e9toffer sa gamme d'alimentations de laboratoire avec la famille R&amp;S NGA100. Elle est compos\u00e9e de quatre mod\u00e8les, dot\u00e9s d\u2019une ou deux sorties d\u00e9livrant pour chacune des voies des tensions et des courants allant jusqu'\u00e0 35 V\/ 6 A ou 100 V \/ 2 A. Les mod\u00e8les mono-voie fournissent une puissance allant jusqu\u2019\u00e0 40 W, alors que celle des mod\u00e8les deux voies atteint 80 W. Les sorties des alimentations double voies peuvent \u00eatre combin\u00e9es pour d\u00e9livrer des tensions ou des courants jusqu'\u00e0 200 V ou 12 A.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/11665\/","og_site_name":"EENewsEurope","article_published_time":"2021-05-26T20:00:27+00:00","og_image":[{"width":911,"height":733,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci9257_rohde_schwarz.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf"},"headline":"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision","datePublished":"2021-05-26T20:00:27+00:00","dateModified":"2021-05-26T20:00:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/"},"wordCount":494,"commentCount":0,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/","url":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/","name":"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2021-05-26T20:00:27+00:00","dateModified":"2021-05-26T20:00:27+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/les-alimentations-de-laboratoire-de-la-gamme-rs-nga100-gagnent-en-precision\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Les alimentations de laboratoire de la gamme R&amp;S NGA100 gagnent en pr\u00e9cision"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364","url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/11665"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=11665"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/11665\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/11666"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=11665"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=11665"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=11665"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=11665"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=11665"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}