{"id":113742,"date":"2017-08-05T22:31:44","date_gmt":"2017-08-05T22:31:44","guid":{"rendered":"https:\/\/\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/"},"modified":"2017-08-05T22:31:44","modified_gmt":"2017-08-05T22:31:44","slug":"de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/","title":{"rendered":"De nouveaux adaptateurs pour les sondes TekProbe Interface"},"content":{"rendered":"<p>Ce nouvel adaptateur R&amp;S&nbsp;RT-Z2T donne aujourd\u2019hui la possibilit\u00e9 d\u2019utiliser les sondes \u00ab TekProbes-BNC \u00bb de Tektronix avec les s\u00e9ries d\u2019oscilloscopes Rohde &amp; Schwarz : RTM3000, RTA4000, RTE1000, RTO2000. L\u2019adaptateur de sondes assure un acc\u00e8s en toute simplicit\u00e9 \u00e0 une vaste gamme de sondes actives, passives, diff\u00e9rentielles, et haute tension. Les sondes doivent simplement \u00eatre connect\u00e9es \u00e0 l\u2019adaptateur qui sera lui-m\u00eame branch\u00e9 \u00e0 l\u2019oscilloscope.<\/p>\n<p>Quelles sondes de la marque Tektronix peuvent \u00eatre utilis\u00e9es avec l\u2019adaptateur&nbsp;RT-Z2T ?<\/p>\n<p>&#8211; Sondes actives uniques : P6205: 750 MHz, 10:1 ; P6243: 1 GHz, 10:1 ; P6245: 1.5 GHz, 10:1 ; P6241: 4 GHz, 10:1 ; P6249: 4 GHz, 5:1<br \/>\n&#8211; Sondes de courant : TCP202: 50 MHz AC\/DC current probe<br \/>\n&#8211; Sondes actives diff\u00e9rentielles : P6246: 400 MHz, 10:1 \/ 1:1 ; P6247: 1 GHz, 10:1 \/ 1:1 ; P6248: 1.5 GHz, 10:1 \/ 1:1 ; P6250: 500 MHz, 50:1 \/ 5:1 ; P6251: 1 GHz, 50:1 \/ 5:1<br \/>\n&#8211; Sondes diff\u00e9rentielles haute tension : P5205: 100 MHz, 50:1 \/ 500:1 ; P5210: 50 MHz, 100:1 \/ 1000:1<br \/>\n&#8211; Sondes optiques : P6701B: 1 GHz ; P6703B: 1.2 GHz ; P6711: 250 MHz ; P6713: 300 MHz<\/p>\n<p><a href=\"http:\/\/www.rohde-schwarz.com\">www.rohde-schwarz.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les nouveaux adapteurs de sondes R&amp;S RT-Z2T permettent d\u2019utiliser les sondes Tektronix de la s\u00e9rie TekProbe-BNC sur les oscilloscopes Rohde &amp; Schwarz. Les sondes Tektronix support\u00e9es peuvent donc d\u00e9sormais \u00eatre connect\u00e9es aux oscilloscopes Rohde &amp; Schwarz via l\u2019adaptateur.<\/p>\n","protected":false},"author":9,"featured_media":113743,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1141],"class_list":["post-113742","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>De nouveaux adaptateurs pour les sondes TekProbe Interface ...<\/title>\n<meta name=\"description\" content=\"Les nouveaux adapteurs de sondes R&amp;S RT-Z2T permettent d\u2019utiliser les sondes Tektronix de la s\u00e9rie TekProbe-BNC sur les oscilloscopes Rohde &amp;...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113742\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"De nouveaux adaptateurs pour les sondes TekProbe Interface\" \/>\n<meta property=\"og:description\" content=\"Les nouveaux adapteurs de sondes R&amp;S RT-Z2T permettent d\u2019utiliser les sondes Tektronix de la s\u00e9rie TekProbe-BNC sur les oscilloscopes Rohde &amp; Schwarz. Les sondes Tektronix support\u00e9es peuvent donc d\u00e9sormais \u00eatre connect\u00e9es aux oscilloscopes Rohde &amp; Schwarz via l\u2019adaptateur.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113742\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2017-08-05T22:31:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci6514_rohde_schwarz.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1890\" \/>\n\t<meta property=\"og:image:height\" content=\"1520\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\"},\"headline\":\"De nouveaux adaptateurs pour les sondes TekProbe Interface\",\"datePublished\":\"2017-08-05T22:31:44+00:00\",\"dateModified\":\"2017-08-05T22:31:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/\"},\"wordCount\":162,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/\",\"name\":\"De nouveaux adaptateurs pour les sondes TekProbe Interface -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2017-08-05T22:31:44+00:00\",\"dateModified\":\"2017-08-05T22:31:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cdn.eenewseurope.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"De nouveaux adaptateurs pour les sondes TekProbe Interface\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"De nouveaux adaptateurs pour les sondes TekProbe Interface ...","description":"Les nouveaux adapteurs de sondes R&amp;S RT-Z2T permettent d\u2019utiliser les sondes Tektronix de la s\u00e9rie TekProbe-BNC sur les oscilloscopes Rohde &amp;...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113742\/","og_locale":"fr_FR","og_type":"article","og_title":"De nouveaux adaptateurs pour les sondes TekProbe Interface","og_description":"Les nouveaux adapteurs de sondes R&amp;S RT-Z2T permettent d\u2019utiliser les sondes Tektronix de la s\u00e9rie TekProbe-BNC sur les oscilloscopes Rohde &amp; Schwarz. Les sondes Tektronix support\u00e9es peuvent donc d\u00e9sormais \u00eatre connect\u00e9es aux oscilloscopes Rohde &amp; Schwarz via l\u2019adaptateur.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113742\/","og_site_name":"EENewsEurope","article_published_time":"2017-08-05T22:31:44+00:00","og_image":[{"width":1890,"height":1520,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci6514_rohde_schwarz.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf"},"headline":"De nouveaux adaptateurs pour les sondes TekProbe Interface","datePublished":"2017-08-05T22:31:44+00:00","dateModified":"2017-08-05T22:31:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/"},"wordCount":162,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/","url":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/","name":"De nouveaux adaptateurs pour les sondes TekProbe Interface -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2017-08-05T22:31:44+00:00","dateModified":"2017-08-05T22:31:44+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/de-nouveaux-adaptateurs-pour-les-sondes-tekprobe-interface\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cdn.eenewseurope.com\/fr\/"},{"@type":"ListItem","position":2,"name":"De nouveaux adaptateurs pour les sondes TekProbe Interface"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364","url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113742"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=113742"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113742\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/113743"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=113742"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=113742"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=113742"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=113742"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=113742"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}