{"id":113122,"date":"2018-08-06T22:31:44","date_gmt":"2018-08-06T22:31:44","guid":{"rendered":"https:\/\/\/photorelais-a-courant-fort-en-boitier-dip4\/"},"modified":"2018-08-06T22:31:44","modified_gmt":"2018-08-06T22:31:44","slug":"photorelais-a-courant-fort-en-boitier-dip4","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/","title":{"rendered":"Photorelais \u00e0 courant fort en bo\u00eetier DIP4"},"content":{"rendered":"<p>En mode puls\u00e9, le courant nominal passe \u00e0 9A pour les deux dispositifs.&nbsp;Le TLP3553A pr\u00e9sente une faible r\u00e9sistance \u00e0 l&rsquo;\u00e9tat passant de seulement 50&nbsp;m\u03a9(maximum), ce qui est moins qu\u2019un relais m\u00e9canique typique (environ 100&nbsp;m\u03a9). Ceci garantit un niveau de pertes minimum lorsque ce dispositif est utilis\u00e9 en remplacement de relais m\u00e9caniques comme ceux de type 1-Form-A que l\u2019on rencontre souvent dans les applications industrielles. Ces&nbsp;photorelais&nbsp;sont con\u00e7us pour fonctionner \u00e0 des temp\u00e9ratures comprises entre -40\u00b0C et +110\u00b0C, ce qui assure une bonne marge thermique au niveau conception. Les TLP3553A et TLP3555A sont disponibles en bo\u00eetier DIP4, en version CMS ou non.<\/p>\n<p><a href=\"http:\/\/toshiba.semicon-storage.com\/eu\/product\/opto\/photocoupler\/detail.TLP3553A.html\">toshiba.semicon-storage.com\/eu\/product\/opto\/photocoupler\/detail.TLP3553A.html<\/a><\/p>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/mosfet-pince-active-pour-drivers-de-relais\">MOSFET \u00e0 pince active pour drivers de relais<\/a><\/h3>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/photocoupleur-driver-de-grille-courant-de-sortie-crete-25a\">Photocoupleur driver de grille \u00e0 courant de sortie cr\u00eate 2,5A<\/a><\/h3>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/ampli-audio-pur-mos-pour-lautomobile\">Ampli audio pur MOS pour l\u2019automobile<\/a><\/h3>\n","protected":false},"excerpt":{"rendered":"<p>Propos\u00e9 par Toshiba Electronics Europe, les deux nouveaux photorelais \u00e0 courant fort TLP3553A et TLP3555A ont une tension de sortie nominale \u00e0 l&rsquo;\u00e9tat OFF (coup\u00e9) de respectivement 30V et 60V, et un courant nominal permanent \u00e0 l&rsquo;\u00e9tat ON (passant) de respectivement 4A et 3A.<\/p>\n","protected":false},"author":9,"featured_media":113123,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1141],"class_list":["post-113122","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Photorelais \u00e0 courant fort en bo\u00eetier DIP4 ...<\/title>\n<meta name=\"description\" content=\"Propos\u00e9 par Toshiba Electronics Europe, les deux nouveaux photorelais \u00e0 courant fort TLP3553A et TLP3555A ont une tension de sortie nominale \u00e0 l&#039;\u00e9tat OFF...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113122\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Photorelais \u00e0 courant fort en bo\u00eetier DIP4\" \/>\n<meta property=\"og:description\" content=\"Propos\u00e9 par Toshiba Electronics Europe, les deux nouveaux photorelais \u00e0 courant fort TLP3553A et TLP3555A ont une tension de sortie nominale \u00e0 l&#039;\u00e9tat OFF (coup\u00e9) de respectivement 30V et 60V, et un courant nominal permanent \u00e0 l&#039;\u00e9tat ON (passant) de respectivement 4A et 3A.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113122\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2018-08-06T22:31:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci6521_toshiba.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"731\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\"},\"headline\":\"Photorelais \u00e0 courant fort en bo\u00eetier DIP4\",\"datePublished\":\"2018-08-06T22:31:44+00:00\",\"dateModified\":\"2018-08-06T22:31:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/\"},\"wordCount\":162,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/\",\"name\":\"Photorelais \u00e0 courant fort en bo\u00eetier DIP4 -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2018-08-06T22:31:44+00:00\",\"dateModified\":\"2018-08-06T22:31:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Photorelais \u00e0 courant fort en bo\u00eetier DIP4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"Photorelais \u00e0 courant fort en bo\u00eetier DIP4 ...","description":"Propos\u00e9 par Toshiba Electronics Europe, les deux nouveaux photorelais \u00e0 courant fort TLP3553A et TLP3555A ont une tension de sortie nominale \u00e0 l'\u00e9tat OFF...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113122\/","og_locale":"fr_FR","og_type":"article","og_title":"Photorelais \u00e0 courant fort en bo\u00eetier DIP4","og_description":"Propos\u00e9 par Toshiba Electronics Europe, les deux nouveaux photorelais \u00e0 courant fort TLP3553A et TLP3555A ont une tension de sortie nominale \u00e0 l'\u00e9tat OFF (coup\u00e9) de respectivement 30V et 60V, et un courant nominal permanent \u00e0 l'\u00e9tat ON (passant) de respectivement 4A et 3A.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113122\/","og_site_name":"EENewsEurope","article_published_time":"2018-08-06T22:31:44+00:00","og_image":[{"width":1024,"height":731,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci6521_toshiba.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf"},"headline":"Photorelais \u00e0 courant fort en bo\u00eetier DIP4","datePublished":"2018-08-06T22:31:44+00:00","dateModified":"2018-08-06T22:31:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/"},"wordCount":162,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/","url":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/","name":"Photorelais \u00e0 courant fort en bo\u00eetier DIP4 -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2018-08-06T22:31:44+00:00","dateModified":"2018-08-06T22:31:44+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/photorelais-a-courant-fort-en-boitier-dip4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Photorelais \u00e0 courant fort en bo\u00eetier DIP4"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364","url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113122"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=113122"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/113122\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/113123"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=113122"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=113122"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=113122"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=113122"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=113122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}