{"id":110106,"date":"2018-09-10T22:31:44","date_gmt":"2018-09-10T22:31:44","guid":{"rendered":"https:\/\/\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/"},"modified":"2018-09-10T22:31:44","modified_gmt":"2018-09-10T22:31:44","slug":"alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii","status":"publish","type":"post","link":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/","title":{"rendered":"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II"},"content":{"rendered":"<p>Les march\u00e9s cibles sont, entre autres, la sant\u00e9, la m\u00e9decine, la dentisterie, les \u00e9quipements de test et mesure, la diffusion et les \u00e9quipements industriels.<\/p>\n<p>Les mod\u00e8les offrent de s\u00e9rie sept tensions de sortie diff\u00e9rentes, mais sur demande d\u2019autres tensions sont disponibles. La plage de tension d\u2019entr\u00e9e va de 85 \u00e0 264&nbsp;Vac, de 47&nbsp;\u00e0 63&nbsp;Hz avec la possibilit\u00e9 d\u2019\u00e9tendre la plage de fr\u00e9quence de 47 \u00e0 440&nbsp;Hz. Pouvant atteindre 94&nbsp;%, le rendement moyen est sup\u00e9rieur \u00e0 87&nbsp;% et la consommation hors charge est inf\u00e9rieure \u00e0 0,5&nbsp;W.<\/p>\n<p>Propos\u00e9es dans quatre types de bo\u00eetier, les alimentations sont destin\u00e9es \u00e0 des installations de classe I ou II (double isolation). Les CUS100ME \u00e0 cadre ouvert mesurent 50,8 x 101,6 x 31,5&nbsp;mm (L x l x h), le ch\u00e2ssis en U 64 x 116 x 38,5 mm ou 64 x 116 x 39,7 mm avec un couvercle. Une version haute de 34,2 mm, \u00e9quip\u00e9e d\u2019une platine m\u00e9tallique, peut \u00e9galement \u00eatre command\u00e9e. Les mod\u00e8les avec platine et profil\u00e9 en U favorisent le refroidissement par conduction des temp\u00e9ratures extr\u00eamement \u00e9lev\u00e9es.<\/p>\n<p>Comme les mod\u00e8les 30&nbsp;W, 60&nbsp;W et 150&nbsp;W de la gamme, le CUS100ME a une tension d\u2019isolation de 4&nbsp;000&nbsp;Vac (2 MoPP) entre l\u2019entr\u00e9e et la sortie, de 1&nbsp;500&nbsp;Vac (1 MoPP) entre l\u2019entr\u00e9e et la masse et de 1&nbsp;500&nbsp;Vac (1 MoPP) entre la sortie et la masse, ce qui lui permet d\u2019\u00eatre utilis\u00e9 dans les \u00e9quipements m\u00e9dicaux de classe B et BF. Le courant de fuite est inf\u00e9rieur \u00e0 250 \u00b5A et le courant de contact inf\u00e9rieur \u00e0 100 \u00b5A. L\u2019altitude maximale de fonctionnement, de transport et de stockage est de 5&nbsp;000 m.<\/p>\n<p>Les certifications de s\u00e9curit\u00e9 incluent les normes CEI\/EN\/ES&nbsp;606011, CEI\/EN\/UL&nbsp;609501, CEI&nbsp;610101 (en cours) et portent aussi le label CE attestant de leur respect des directives Basse tension, CEM et RoHS2. Une variante conforme \u00e0 EN 603351 est disponible sur demande. Les alimentations sont \u00e9galement conformes \u00e0 EN&nbsp;55011B et EN&nbsp;55032B en mati\u00e8re d\u2019\u00e9missions conduites et rayonn\u00e9es (classe I et II) et r\u00e9pondent aux exigences de la norme EN&nbsp;6100032 relative aux courants harmoniques et des normes CEI 6060112 \u00e9dition 4 et CEI 610004 relatives \u00e0 l\u2019immunit\u00e9.<\/p>\n<p><a href=\"http:\/\/www.fr.tdk-lambda.com\/cus100me%20\">www.fr.tdk-lambda.com\/cus100me<\/a><\/p>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/des-alimentations-en-boitier-compact-extraplat\">Des alimentations en bo\u00eetier compact extraplat<\/a><\/h3>\n<h3 class=\"title\"><a href=\"http:\/\/www.electronique-eci.com\/news\/convertisseurs-dc-dc-pour-environnements-difficiles\">Convertisseurs DC-DC pour environnements difficiles <\/a><\/h3>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>TDK Corporation annonce le lancement sous la marque TDK-Lambda de la gamme d\u2019alimentations \u00e9lectriques AC-DC m\u00e9dicales et industrielles CUS100ME  de 100 W nominale. Les alimentations d\u00e9livrent une puissance de 75 W sur une plage de temp\u00e9rature ambiante pouvant atteindre 85\u00b0 C avec un flux d\u2019air de 1 m\/s seulement, mais avec un refroidissement par conduction, elles sont en mesure de d\u00e9livrer une puissance totale de 100W jusqu\u2019\u00e0 une temp\u00e9rature ambiante de 70\u00b0C.<\/p>\n","protected":false},"author":9,"featured_media":110107,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[881],"tags":[],"domains":[47],"ppma_author":[1141],"class_list":["post-110106","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nouveaux-produits","domains-electronique-eci"],"acf":[],"yoast_head":"<title>Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II ...<\/title>\n<meta name=\"description\" content=\"TDK Corporation annonce le lancement sous la marque TDK-Lambda de la gamme d\u2019alimentations \u00e9lectriques AC-DC m\u00e9dicales et industrielles CUS100ME  de 100...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/110106\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II\" \/>\n<meta property=\"og:description\" content=\"TDK Corporation annonce le lancement sous la marque TDK-Lambda de la gamme d\u2019alimentations \u00e9lectriques AC-DC m\u00e9dicales et industrielles CUS100ME de 100 W nominale. Les alimentations d\u00e9livrent une puissance de 75 W sur une plage de temp\u00e9rature ambiante pouvant atteindre 85\u00b0 C avec un flux d\u2019air de 1 m\/s seulement, mais avec un refroidissement par conduction, elles sont en mesure de d\u00e9livrer une puissance totale de 100W jusqu\u2019\u00e0 une temp\u00e9rature ambiante de 70\u00b0C.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/110106\/\" \/>\n<meta property=\"og:site_name\" content=\"EENewsEurope\" \/>\n<meta property=\"article:published_time\" content=\"2018-09-10T22:31:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci6564_tdk.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2100\" \/>\n\t<meta property=\"og:image:height\" content=\"1500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alain Dieul\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alain Dieul\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/\"},\"author\":{\"name\":\"Alain Dieul\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\"},\"headline\":\"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II\",\"datePublished\":\"2018-09-10T22:31:44+00:00\",\"dateModified\":\"2018-09-10T22:31:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/\"},\"wordCount\":413,\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"articleSection\":[\"Nouveaux produits\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/\",\"url\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/\",\"name\":\"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II -\",\"isPartOf\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\"},\"datePublished\":\"2018-09-10T22:31:44+00:00\",\"dateModified\":\"2018-09-10T22:31:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecinews.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#website\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"name\":\"EENewsEurope\",\"description\":\"Just another WordPress site\",\"publisher\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#organization\",\"name\":\"EENewsEurope\",\"url\":\"https:\/\/www.eenewseurope.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"contentUrl\":\"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg\",\"width\":283,\"height\":113,\"caption\":\"EENewsEurope\"},\"image\":{\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf\",\"name\":\"Alain Dieul\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g\",\"caption\":\"Alain Dieul\"}}]}<\/script>","yoast_head_json":{"title":"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II ...","description":"TDK Corporation annonce le lancement sous la marque TDK-Lambda de la gamme d\u2019alimentations \u00e9lectriques AC-DC m\u00e9dicales et industrielles CUS100ME  de 100...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/110106\/","og_locale":"fr_FR","og_type":"article","og_title":"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II","og_description":"TDK Corporation annonce le lancement sous la marque TDK-Lambda de la gamme d\u2019alimentations \u00e9lectriques AC-DC m\u00e9dicales et industrielles CUS100ME de 100 W nominale. Les alimentations d\u00e9livrent une puissance de 75 W sur une plage de temp\u00e9rature ambiante pouvant atteindre 85\u00b0 C avec un flux d\u2019air de 1 m\/s seulement, mais avec un refroidissement par conduction, elles sont en mesure de d\u00e9livrer une puissance totale de 100W jusqu\u2019\u00e0 une temp\u00e9rature ambiante de 70\u00b0C.","og_url":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/110106\/","og_site_name":"EENewsEurope","article_published_time":"2018-09-10T22:31:44+00:00","og_image":[{"width":2100,"height":1500,"url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/import\/default\/files\/sites\/default\/files\/images\/eci6564_tdk.jpg","type":"image\/jpeg"}],"author":"Alain Dieul","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alain Dieul","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/#article","isPartOf":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/"},"author":{"name":"Alain Dieul","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf"},"headline":"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II","datePublished":"2018-09-10T22:31:44+00:00","dateModified":"2018-09-10T22:31:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/"},"wordCount":413,"publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"articleSection":["Nouveaux produits"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/","url":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/","name":"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II -","isPartOf":{"@id":"https:\/\/www.eenewseurope.com\/en\/#website"},"datePublished":"2018-09-10T22:31:44+00:00","dateModified":"2018-09-10T22:31:44+00:00","breadcrumb":{"@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecinews.fr\/fr\/alimentations-2-x-4-de-100-w-homologuees-classes-i-et-ii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecinews.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Alimentations 2\u201d x 4\u201d de 100 W homologu\u00e9es classes I et II"}]},{"@type":"WebSite","@id":"https:\/\/www.eenewseurope.com\/en\/#website","url":"https:\/\/www.eenewseurope.com\/en\/","name":"EENewsEurope","description":"Just another WordPress site","publisher":{"@id":"https:\/\/www.eenewseurope.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eenewseurope.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.eenewseurope.com\/en\/#organization","name":"EENewsEurope","url":"https:\/\/www.eenewseurope.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","contentUrl":"https:\/\/www.ecinews.fr\/wp-content\/uploads\/2022\/02\/logo-1.jpg","width":283,"height":113,"caption":"EENewsEurope"},"image":{"@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/568c789a4794bd460460501ba91f5daf","name":"Alain Dieul","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.eenewseurope.com\/en\/#\/schema\/person\/image\/6d32dc651fbcef3b338066625b118364","url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","caption":"Alain Dieul"}}]}},"authors":[{"term_id":1141,"user_id":9,"is_guest":0,"slug":"alaindieul","display_name":"Alain Dieul","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/93708ec89b35deb10f4cfbfe144b4e07?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/110106"}],"collection":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/comments?post=110106"}],"version-history":[{"count":0,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/posts\/110106\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media\/110107"}],"wp:attachment":[{"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/media?parent=110106"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/categories?post=110106"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/tags?post=110106"},{"taxonomy":"domains","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/domains?post=110106"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.ecinews.fr\/fr\/wp-json\/wp\/v2\/ppma_author?post=110106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}