{"version":"1.0","provider_name":"EENewsEurope","provider_url":"https:\/\/www.ecinews.fr\/fr\/","author_name":"eeNews Europe","author_url":"https:\/\/www.ecinews.fr\/fr\/author\/eenews-europe\/","title":"Les risques du test d'isolation","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"BmobB2HZpw\"><a href=\"https:\/\/www.ecinews.fr\/fr\/white_papers\/les-risques-du-test-disolation\/\">Les risques du test d&rsquo;isolation<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.ecinews.fr\/fr\/white_papers\/les-risques-du-test-disolation\/embed\/#?secret=BmobB2HZpw\" width=\"600\" height=\"338\" title=\"\u00ab\u00a0Les risques du test d&rsquo;isolation\u00a0\u00bb &#8212; EENewsEurope\" data-secret=\"BmobB2HZpw\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script type=\"text\/javascript\">\n\/* <![CDATA[ *\/\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/* ]]> *\/\n<\/script>\n","thumbnail_url":"https:\/\/www.eenewseurope.com\/wp-content\/uploads\/import\/default\/files\/import\/eci1807_xp.jpg","thumbnail_width":607,"thumbnail_height":476,"description":"Hipot est l'abr\u00e9viation de\u00a0 \u201chigh potential\u201d\u00a0\u00a0 une cat\u00e9gorie de tests \u00e9lectriques utilis\u00e9e pour v\u00e9rifier l'efficacit\u00e9 de l'isolation \u00e9lectrique des transformateurs, des moteurs, des circuits imprim\u00e9s, des sous ensembles \u00e9lectriques (comme les alimentations) et des \u00e9quipements finaux. Il est aussi connu sous le nom de rigidit\u00e9 di\u00e9lectrique.  Les \u00e9quipements \u00e9lectriques raccord\u00e9s au secteur alternatif doivent passer des tests ''types'' demand\u00e9s par les agences de s\u00e9curit\u00e9 . Les normes communes sont l' IEC60950-1 pour les \u00e9quipements industriels et informatiques et l\u2019 IEC60601-1 pour les \u00e9quipements m\u00e9dicaux. Avant d\u2019envoyer des \u00e9quipements pour ces tests, les fabricants d\u2019alimentations, veulent g\u00e9n\u00e9ralement s\u2019assurer qu\u2019ils r\u00e9pondent aux normes en effectuant leurs propres tests. Toutefois, les sp\u00e9cifications de tests peuvent \u00eatre mal interpr\u00e9t\u00e9es, entrainant des dommages aux alimentations et retardant l\u2019homologation d\u2019un produit qui doit \u00eatre mis sur le march\u00e9.  Cet article fournit de larges\u00a0 informations sur ce qui est demand\u00e9 \u00e0 un fabricant d\u2019\u00e9quipements pour r\u00e9pondre \u00e0 ces tests. Il fait r\u00e9f\u00e9rence en premier aux \u00e9quipements de classe I, les diff\u00e9rences pour les \u00e9quipements de classe II sont d\u00e9taill\u00e9es s\u00e9par\u00e9ment."}